Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change upgrade port_failover_switch

change upgrade port_failover_switch

Function

The change upgrade port_failover_switch command is used to enable or disable the failover function for SAN service ports in an upgrade.

Format

change upgrade port_failover_switch switch=?

Parameters

Parameter

Description

Value

switch Whether to enable the failover function for SAN service ports in an upgrade.

The value can be "on" or "off", where:

  • "on": enables the failover function in an upgrade.
  • "off": disables the failover function in an upgrade.
The default switch status of the failover function in an upgrade is "on".

Views

Developer view

Usage Guidelines

Before performing this operation, determine whether the modification is necessary. If the switch of the failover function is modified during an upgrade, the modification takes effect temporarily and does not persist. After controllers are restarted, the switch is restored to the status before the modification.

OceanStor 18500 V5, 18500F V5, 18800 V5 and 18800F V5 storage systems support this command.

Example

Disable the failover function for SAN service ports in an upgrade.

developer:/>change upgrade port_failover_switch switch=off
Command executed successfully.

System Response

None