Advanced O&M Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change ddp limit_time

change ddp limit_time

Function

The change ddp limit_time command is used to set time parameters of the deduplication flow control function to optimize deduplication performance.

Format

change ddp limit_time type=? up_limit_time=? down_limit_time=? controller=? [ version=? ]

Parameters

Parameter

Description

Value

type

Optimization type.

The value can be "file_system" or "row_lun", where:

  • "file_system": file system.
  • "row_lun": deduplication and compression LUNs.

up_limit_time

Upper limit value of the deduplication flow control time (unit: ms). When the transaction flushing time is greater than the value, the system will increase the flow control on deduplication I/Os.

The value is an integer greater than the down_limit_time value.

down_limit_time

Lower limit value of the deduplication flow control time (unit: ms). When the transaction flushing time is lower than the value, the system will reduce the flow control on deduplication I/Os.

The value is an integer less than the up_limit_time value.

controller

Controller ID.

The value is in the format of "XA", "XB", "XC", or "XD", where "X" indicates an integer from "0" to "3", for example, "0A" or "1C".

version

Deduplication version.

The value can be "0" or "1", where:

  • "0": version before the deduplication performance is optimized.
  • "1": version after the deduplication performance is optimized.

Views

Developer view

Usage Guidelines

  • This command is used to optimize the deduplication performance of file systems and LUNs.
  • When this command is executed, the controller ID must be specified and this command takes effect only on this controller.

Example

For the deduplication flow control function of file systems, change the upper limit of time to 1000 ms and the lower limit of time to 800 ms.

developer:/>change ddp limit_time type=file_system up_limit_time=1000 down_limit_time=800 controller=0A 
Command executed successfully.