This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change disk diskin

change disk diskin

Function

The change disk diskin command is used to enable/disable disk connection failure upon disk setting failure.

Format

change disk diskin modeselect_switch=?

Parameters

Parameter

Description

Value

modeselect_switch=?

To enable or disable the function.

The value can be "on" or "off", where:

  • on:enable the function.
  • off:disable the function.

Views

Developer view

Usage Guidelines

  • This function is enabled by default.
  • Disable this function if the disk connection failure is caused by disk setting failure. Then reinsert the disk and connect it to the storage array.
  • After the disk is successfully connected, enable this function.

Example

Disable disk connection failure upon disk setting failure.

developer:/>change disk diskin modeselect_switch=off 
DANGER: You are about to disable connection restriction upon disk setting failure. This operation may allow other disks to connect to the storage array and use the malfunctioning disk when the ERC fails to be set or write cache fails to be disabled, resulting in data loss risks. 
Suggestion: Before performing this operation, ensure that connection restriction upon disk setting failure needs to be disabled. Ensure that: 
1. This command is used only for data recovery. 
2. Data will not be written to the malfunctioning disk. 
3. The "change disk diskin modeselect_switch=on" command is executed to enable connection restriction upon disk setting failure after data is recovered. 
Have you read danger alert message carefully?(y/n)y 
Are you sure you really want to perform the operation?(y/n)y 