Advanced O&M Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
os setallip

os setallip

Function

The os setallip command is used to modify the IP address configuration file of management ports on a switch.

Format

os setallip dsw0ip0=? dsw0ip1=? dsw1ip0=? dsw1ip1=?

Parameters

Parameter

Description

Value

dsw0ip0=?

IP address of management port 0 of the switch on plane 0.

Valid IP address.

dsw0ip1=?

IP address of management port 1 of the switch on plane 0.

Valid IP address.

dsw1ip0=?

IP address of management port 0 of the switch on plane 1.

Valid IP address.

dsw1ip1=?

IP address of management port 1 of the switch on plane 1.

Valid IP address.

Views

Diagnostic view

Usage Guidelines

  • This command can be used to modify the IP address configuration file of management ports on the local switch only. To modify the IP address configuration file of management ports on another switch, log in to the switch and run this command.
  • Before running this command, ensure that plane numbers have been configured on the switch.
  • Ensure that no node resets during the configuration.
  • After this command is executed, the switch will restart.

Example

Modify the IP address configuration file of management ports on a switch.

_user_admin:/diagnose>os setallip 172.16.126.142 172.16.128.142 172.16.128.143 172.16.127.147 
Modify dsw ip in config file success. 
The system is going to restart.

System Response

None