Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
cliget -d iocardbaseinfo

cliget -d iocardbaseinfo

Function

The cliget -d iocardbaseinfo command is used to query information about interface modules.

Format

cliget -d iocardbaseinfo <slotnum>

Parameters

Parameter

Description

Value

slotnum Slot ID.

For a 2 U entry-level controller enclosure, the value is from 0 to 2.

For a 2 U midrange controller enclosure, the value is from 0 to 5.

For a 4 U high-end controller enclosure, the value is from 0 to 27.

Modes

serial port mode

Usage Guidelines

OceanStor 18500 V5 Kunpeng, 18500F V5 Kunpeng, 18800 V5 Kunpeng and 18800F V5 Kunpeng storage systems support this command.

Example

Query the information about the interface module in slot "1". The command output varies depending on a specific product.

iBMC:/->cliget -d iocardbaseinfo 1
slotId       : 1
PCBVer       : 0
TypeErr      : 0
CardType     : 0x243
Qos.mode     : 0x1
Qos.speed    : 0x15
HiLinkType   : 3
Temp0        : 57
Temp1        : 30719
Temp2        : 30719
ErrCode      : 0
UpgradeStatus: 0
MCuversion   :     
    HwVer    : 0    
    PcbVer   : 0    
    SoftVer  : 10.01.01T43

System Response

The following table describes the parameter meanings.

Parameter

Meaning

slotId

Slot ID.

PCBVer

PCB version number.

TypeErr

Type error status.

CardType

Card type.

Qos.mode

QoS mode.

Qos.speed

QoS speed.

HiLinkType

HiLink type.

Temp0

Temperature 0.

Temp1

Temperature 1.

Temp2

Temperature 2.

ErrCode

Error code.

UpgradeStatus

Upgrade status.

MCuVersion

MCU version number.

HwVer

Hardware version number.

PcbVer

PCB version number.

softVer

Software version number.