Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show fdsa check_item

show fdsa check_item

Function

The show fdsa check_item command is used to show information about all check items in the FDSA system.

Format

show fdsa check_item

Parameters

None

Views

Developer view

Usage Guidelines

You can run the "show fdsa check_item_switch" command to view all check item information including the names and switch states of check items, and run the "change fdsa check_item_switch" command to change the switch state of a specified check item.

Example

Show information about all check items in the FDSA.

developer:/>show fdsa check_item
 
  Name                              Type    Status        Switch  Heal Time One Day  Fault Level
  --------------------------------  ------  ------------  ------  -----------------  -----------
  SNMPAGENT_CPU_RSC                 User    WAITCHECKING  On      0                  None
  SNMPAGENT_MEM_RSC                 User    WAITCHECKING  On      0                  None
  SNMPAGENT_HANDLE_RSC              User    WAITCHECKING  On      0                  None

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Name

Name of a check item.

Type

Type of a check item.

Status

Status of a check item.

Switch

Switch of a check item.

Heal Time One Day

Number of times that a check item heals itself within one day.

Fault Level

Severity of a check item fault.