This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5500 V5, 5600 V5, 5800 V5, 6800 V5, 5300F V5, 5500F V5, 5600F V5, 5800F V5, and 6800F V5. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
pair showSyncStatics

pair showSyncStatics

Function

The pair showSyncStatics command is used to query statistics about operations on the file object during synchronization.

Format

pair showSyncStatic pairID

Parameters

Parameter

Description

Value

PairID

Pair object ID.

To obtain the value, run the "pair showobjs" command.

Views

Diagnostic view

Usage Guidelines

Query file copy information during the file copy process.

Example

  • Query statistics about operations on file objects of the pair whose ID is "0" during incremental synchronization.
    admin:/diagnose>pair showSyncStatics 0 
    Now it is resync. 
             
      read     objectnum                    : 9
  • Query statistics about operations on file objects of the pair whose ID is "1" during initial synchronization.
    admin:/diagnose>pair showSyncStatics 1 
    Now it is initial sync. 
                 
      listed  objectnum                     : 240             
      opened  objectnum                     : 240             
      read objectnum                     : 52

System Response

The following table describes the parameter meanings.

Parameter

Meaning

read objectnum

Number of obtained objects.

listed objectnum

Number of opened objects.

opened objectnum

Number of objects that have been read.