This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5500 V5, 5600 V5, 5800 V5, 6800 V5, 5300F V5, 5500F V5, 5600F V5, 5800F V5, and 6800F V5. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
drvfcoe showall

drvfcoe showall

Function

The drvfcoe showall command is used to view information about all Fibre Channel over Ethernet (FCoE) ports.

Format

drvfcoe showall

Parameters

None

Views

Diagnostic view

Usage Guidelines

None

Example

View information about all FCoE ports.

admin:/diagnose>drvfcoe showall 
+----------------------------------------------------------------------------------+ 
|netif |portid |mac |type |service_type|fc_portid|wwpn |stat | 
+----------------------------------------------------------------------------------+ 
|eth4 |20300 |000102030100|VN2VF |TGT |000000000|2000000102030100|00000b| 
+----------------------------------------------------------------------------------+ 
|eth5 |20301 |000102030108|VN2VF |TGT |000000000|2000000102030108|00000b| 
+----------------------------------------------------------------------------------+ 
|eth6 |20302 |000102030110|VN2VF |TGT |000000000|2000000102030110|00000b| 
+----------------------------------------------------------------------------------+ 
|eth7 |20303 |000102030118|VN2VF |TGT |000980000|2000000102030118|000009| 
+----------------------------------------------------------------------------------+ 
Show Vlan Info: 
------------------------------------------------------------------------------------ 
eth4 Vlan Id:1 Vlan Req Cnt:0. 
eth5 Vlan Id:1 Vlan Req Cnt:0. 
eth6 Vlan Id:1 Vlan Req Cnt:0. 
eth7 Vlan Id:568 Vlan Req Cnt:3. 
Show Neighbor List: 
------------------------------------------------------------------------------------ 
local: 
eth4 [0x00020300] 
Neighbor: 
N/A 
local: 
eth5 [0x00020301] 
Neighbor: 
N/A 
local: 
eth6 [0x00020302] 
Neighbor: 
N/A 
local: 
eth7 [0x00020303] 
Neighbor: 
portid:980001 WWPN:0x10000000c9b81425 WWNN:0x20000000c9b81425 role:2 state:4 
Total session: 1

System Response

The following table describes the parameter meanings.

Parameter

Meaning

netif

Ethernet port name.

portid

Port ID.

mac

MAC address.

type

Port type.

service_type

Service type.

fc_portid

ID allocated to a Fibre Channel port.

wwpn

Port WWPN.

stat

Port status.

Vlan Id

VLAN ID.

Vlan Req Cnt

Count of VLAN requests.

Neighbor

Information about the neighboring node.

Total session

Total number of port connections.