No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 5000, 5000F, 6000, and 6000F V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5500 V5, 5600 V5, 5800 V5, 6800 V5, 5300F V5, 5500F V5, 5600F V5, 5800F V5, and 6800F V5. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change tgt_switch storage_work_mode

change tgt_switch storage_work_mode

Function

The change tgt_switch storage_work_mode command is used to change the A/A work mode of a storage device.

Format

change tgt_switch storage_work_mode switch=?

Parameters

Parameter

Description

Value

switch

Whether the A/A work mode of a storage device is enabled.

-

Views

Developer view

Usage Guidelines

  • If the A/A work mode is enabled, the host or gateway installed with Veritas DMP identifies the storage device as the A/A type.
  • If the A/A work mode is disabled, the host or gateway installed with Veritas DMP identifies the single- and dual-controller storage device as the A/A-A type, and identifies the multi-controller storage device as the A/A type.

Example

Change the A/A work mode of a storage device.

developer:/>change tgt_switch storage_work_mode switch=on 
DANGER: You are about to change the A/A work mode of the storage device. If the Veritas DMP software is installed on the host or gateway and the Veritas DMP software takes over LUNs mapped from the storage device, this operation will cause the LUNs to be offline.  
Suggestion: Check whether the Veritas DMP software is installed on the host or gateway connected to the storage device and whether the Veritas DMP software takes over the LUNs mapped from the storage device. If yes, stop services on these LUNs, change the work mode, and restart the host. 
Have you read warning message carefully?(y/n)y 

Are you sure you really want to perform the operation?(y/n)y 
Command executed successfully. 

System Response

None