No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 5000, 5000F, 6000, and 6000F V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5500 V5, 5600 V5, 5800 V5, 6800 V5, 5300F V5, 5500F V5, 5600F V5, 5800F V5, and 6800F V5. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change disk_bom list_config

change disk_bom list_config

Function

The change disk_bom list_config command is used to set the switch of the disk access check function.

Format

change disk_bom list_config switch=?

Parameters

Parameter

Description

Value

switch

Switch status of the disk access check function.

The value is "on" or "off", where:

  • "on": enables the disk access check function.
  • "off": disables the disk access check function.

Views

Developer view

Usage Guidelines

In the disk access process, do not run the command.

Example

Enable the disk access check function.

developer:/>change disk_bom list_config switch=on 
WARNING: You are about to modify the switch of the disk connection check function. This operation may change whether the disk can be connected to the system. 
Suggestion: Before performing the operation, confirm whether connection check is performed on disks on the storage array. 
Have you read warning message carefully?(y/n)y 
Are you sure you really want to perform the operation?(y/n)y 
Command executed successfully. 

System Response

None

Translation
Download
Updated: 2019-07-11

Document ID: EDOC1000181619

Views: 639398

Downloads: 256

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next