No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 5000, 5000F, 6000, and 6000F V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5500 V5, 5600 V5, 5800 V5, 6800 V5, 5300F V5, 5500F V5, 5600F V5, 5800F V5, and 6800F V5. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show disk_reliability_policy slow_disk_detect

show disk_reliability_policy slow_disk_detect

Function

The show disk_reliability_policy slow_disk_detect command is used to set related parameters of slow disk detection.

Format

show disk_reliability_policy slow_disk_detect

Parameters

None

Views

Developer view

Usage Guidelines

None

Example

Query related parameters of slow disk detection.

developer:/>show disk_reliability_policy slow_disk_detect 
  Detect Switch                  : On  
  Detect Isolate Diagnose Switch : Off  
  Detect Threshold Multiple      : 5 
  Detect Minor Cycle Time        : 30  
  Detect Slow Cycle Count        : 6 
  Detect Permit Slow Disk Count  : 4 
  Detect Min Threshold Value     : 10  
  Detect Max Threshold Value     : 50 
  Detect Permit Slow Disk Time : 30

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Detect Switch

Switch of the slow disk detection function.

Detect Isolate Diagnose Switch

Switch of the isolation diagnosis feature.

Detect Threshold Multiple

Threshold multiplier for determining slow disks.

Detect Minor Cycle Time

Short period (unit: s).

Detect Slow Cycle Count

Number of slow periods.

Detect Permit Slow Disk Count

Maximum number of slow disks allowed to be reported within a period.

Detect Min Threshold Value

Minimum threshold for determining mean service time of slow periods (unit: ms).

Detect Max Threshold Value

Maximum threshold for determining mean service time of slow periods (unit: ms).

Detect Permit Slow Disk Time

Period of slow disks allowed to be reported (unit: day).

Translation
Download
Updated: 2019-07-11

Document ID: EDOC1000181619

Views: 582050

Downloads: 233

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share