This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5500 V5, 5600 V5, 5800 V5, 6800 V5, 5300F V5, 5500F V5, 5600F V5, 5800F V5, and 6800F V5. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
cliget -d boardalarm

cliget -d boardalarm

Function

The cliget -d boardalarm command is used to query the status of alarms on a board.

Format

cliget -d boardalarm

Parameters

None

Modes

serial port mode

Usage Guidelines

None

Example

Query the status of alarms on a board.

administrator@SMM_6U / $ cliget -d boardalarm 
AlarmName | ID | Type | State | MaxChan | Enable 
Lm75Bus11Alarm | 0 | 0 | 0 | 1 | 0 
9545Bus0Alarm | 1 | 6 | 0 | 4 | 1 
9545Bus1Alarm | 2 | 6 | 0 | 4 | 1 
9545Bus2Alarm | 3 | 6 | 0 | 4 | 1 
9545Bus3Alarm | 4 | 6 | 0 | 4 | 1 
9545Bus4Alarm | 5 | 6 | 0 | 4 | 1 
GE0Alarm | 6 | 39 | 0 | 1 | 1 
GE1Alarm | 7 | 39 | 0 | 1 | 1 
Switch6352 | 8 | 41 | 0 | 1 | 1 
Switch6185A | 9 | 41 | 0 | 1 | 1 
Switch6185B | 10 | 41 | 0 | 1 | 1 
Switch6185C | 11 | 41 | 0 | 1 | 1 
Switch6185D | 12 | 41 | 0 | 1 | 1 
PSOnAlarm | 13 | 42 | 0 | 1 | 0 
PSOffAlarm | 14 | 42 | 0 | 1 | 0 
EccAlarm | 15 | 40 | 0 | 1 | 1 
Usb5VAlarm | 16 | 43 | 0 | 1 | 1 
CpldAlarm | 17 | 9 | 0 | 1 | 1 
OppSmmAlarm | 18 | 64 | 0 | 1 | 0 
TDMAlarm | 19 | 44 | 0 | 1 | 1 
BmcFlashAlarm | 20 | 21 | 0 | 1 | 1 
CtrlA8796AAlarm | 21 | 48 | 0 | 1 | 0 
CtrlA8796BAlarm | 22 | 48 | 0 | 1 | 0 
CtrlA8717AAlarm | 23 | 49 | 0 | 1 | 0 
CtrlA8717BAlarm | 24 | 49 | 0 | 1 | 0 
CtrlARTAlarm | 25 | 50 | 0 | 1 | 0 
CtrlB8796AAlarm | 26 | 48 | 0 | 1 | 0 
CtrlB8796BAlarm | 27 | 48 | 0 | 1 | 0 
CtrlB8717AAlarm | 28 | 49 | 0 | 1 | 0 
CtrlB8717BAlarm | 29 | 49 | 0 | 1 | 0 
CtrlBRTAlarm | 30 | 50 | 0 | 1 | 0 
CtrlC8796AAlarm | 31 | 48 | 0 | 1 | 0 
CtrlC8796BAlarm | 32 | 48 | 0 | 1 | 0 
CtrlC8717AAlarm | 33 | 49 | 0 | 1 | 0 
CtrlC8717BAlarm | 34 | 49 | 0 | 1 | 0 
CtrlCRTAlarm | 35 | 50 | 0 | 1 | 0 
CtrlD8796AAlarm | 36 | 48 | 0 | 1 | 0 
CtrlD8796BAlarm | 37 | 48 | 0 | 1 | 0 
CtrlD8717AAlarm | 38 | 49 | 0 | 1 | 0 
CtrlD8717BAlarm | 39 | 49 | 0 | 1 | 0 
CtrlDRTAlarm | 40 | 50 | 0 | 1 | 0

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Lm75Bus11Alarm

Lm75 status.

9545Bus0Alarm

9545 bus status.

9545Bus1Alarm

9545 bus status.

9545Bus2Alarm

9545 bus status.

9545Bus3Alarm

9545 bus status.

9545Bus4Alarm

9545 bus status.

GE0Alarm

GE 0 status.

GE1Alarm

GE 1 status.

Switch6352Alarm

6352 status.

Switch6185AAlarm

6185A status.

Switch6185BAlarm

6185B status.

Switch6185CAlarm

6185C status.

Switch6185DAlarm

6185D status.

PsOnAlarm

Power supply PsOn status.

PSOffAlarm

Power supply Psoff status.

EccAlarm

ECC status.

Usb5VAlarm

USB 5 V status.

CpldAlarm

CPLD status.

OppSmmAlarm

Opposite SMM status.

TDMAlarm

TDM status.

BmcFlashAlarm

BMC flash status.

CtrlA8796AAlarm

CtrlA 8796A status.

CtrlA8796BAlarm

CtrlA 8796B status.

CtrlA8717AAlarm

CtrlA 8717A status.

CtrlA8717BAlarm

CtrlA 8717B status.

CtrlARTAlarm

CtrlA RT status.

CtrlB8796AAlarm

CtrlB 8796A status.

CtrlB8796BAlarm

CtrlB 8796B status.

CtrlB8717AAlarm

CtrlB 8717A status.

CtrlB8717BAlarm

CtrlB 8717B status.

CtrlBRTAlarm

CtrlB RT status.

CtrlC8796AAlarm

CtrlC 8796A status.

CtrlC8796BAlarm

CtrlC 8796B status.

CtrlC8717AAlarm

CtrlC 8717A status.

CtrlC8717BAlarm

CtrlC 8717B status.

CtrlCRTAlarm

CtrlC RT status.

CtrlD8796AAlarm

CtrlD 8796A status.

CtrlD8796BAlarm

CtrlD 8796B status.

CtrlD8717AAlarm

CtrlD 8717A status.

CtrlD8717BAlarm

CtrlD 8717B status.

CtrlDRTAlarm

CtrlD RT status.