This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, 6800F V5, 18500 V5, 18500F V5, 18800 V5, and 18800F V5. This document describes the procedure for replacing the parts of storage system in terms of safety operations, preparations, and precautions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Replacing an AC Power Module

Replacing an AC Power Module

This section describes how to replace an AC power module.

Impact on the System

During the replacement of a power module, if the redundant power module fails, the corresponding quorum server is unexpectedly powered off, causing all services in the quorum server to be interrupted.

Prerequisites

  • When two power modules are configured, remove one power module without powering off the quorum server if the other power module is operating properly and its power rating is greater than or equal to the rated power of the quorum server.
  • You have determined the position on the quorum server for removing a power module.
  • You have obtained the rack number and chassis number of the quorum server.
  • You have located the quorum server based on the preceding information, and labeled its panel to prevent misoperations.
  • The spare part is ready.

Tools and Materials

  • ESD gloves or ESD wrist strap
  • Packaging materials, for example, an ESD bag

Procedure

  1. (Optional) If only one power module is configured, power off the quorum server.
  2. Remove the AC power module.

    1. Open the cable tie for the power cable. See Figure 6-229.
      Figure 6-229 Opening a cable tie

    2. Remove the power cable from the power module to be replaced. See Figure 6-230.
      Figure 6-230 Removing a power cable

    3. Press the spring on the power module in the arrow direction, and pull the power module out of the slot while holding the handle. See steps (1) and (2) in Figure 6-231.
      Figure 6-231 Removing a power module

    4. Place the removed power module in an ESD bag.

  3. Install the AC power module.

    1. Take the spare AC power module out of the ESD bag.
    2. Push the spare AC power module along the guide rails into a slot until you hear a click.
      The power module spring snaps into the latch so that the power module does not move. See Figure 6-232.
      Figure 6-232 Installing an AC power module

    3. Connect the power cable to the power module. See Figure 6-233.
      Figure 6-233 Connecting a power cable to an AC power module

    4. Secure the power cable using a cable tie. See Figure 6-234.
      Figure 6-234 Securing a power cable

  4. (Optional) If only one power module is configured, power on the quorum server.