Parts Replacement

OceanStor V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, 6800F V5, 18500 V5, 18500F V5, 18800 V5, and 18800F V5. This document describes the procedure for replacing the parts of storage system in terms of safety operations, preparations, and precautions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Replacing a Power Module (for 18000 V5/18000F V5 Series)

Replacing a Power Module (for 18000 V5/18000F V5 Series)

This section describes how to replace a power module.

Impact on the System

During the replacement of a power module, if the redundant power module fails, the corresponding controller is powered by a BBU and the system reliability degrades.

Prerequisites

  • The spare part of the power module is ready.
  • The power module that you want to replace has been located.
NOTE:

You can locate a component in either of the following ways:

  • Log in to DeviceManager, and go to the System page. On the System page, check the device view and locate the position of the component to be replaced. If the component has a location indicator, turn on the indicator. (For details about how to turn on a location indicator, see the online help of DeviceManager.)
  • Use the alarm indicator of the component to locate its component.
  • The power cable has been disconnected from the power module that you want to replace.
  • The other power modules work properly.

Precautions

  • Do not touch the connectors of a power module and a power cable.
  • Remove and insert a power module with even force. Excessive force may damage the appearance or connectors of the power module.
  • Remove only one power module at a time.
  • A power module must be replaced within five minutes. Otherwise, the system heat dissipation is compromised.

Tools and Materials

  • ESD wrist strap
  • ESD bag
  • Labels
  • Phillips screwdriver

Procedure

  1. Perform a pre-replacement check.

    Check whether there is a redundant power module and whether the Running/Alarm indicator of the redundant power module is steady green, as shown in Figure 5-35. For details about the indicators on different components, see Running/Alarm Indicators on a 6 U Controller Enclosure.
    Figure 5-35 Running/Alarm indicator on a power module

    You can perform replacement only when a redundant power module exists and the redundant power module is working properly.

  2. Wear an ESD wrist strap.
  3. Press the latch on the inner side of the power module handle and pull out the power module, as shown in Figure 5-36.

    Figure 5-36 Removing an AC power module

  4. Put the removed power module into an ESD bag.
  5. Take the replacement power module out of its ESD bag.
  6. Insert the replacement power module into the empty slot until it clicks into place, as shown in Figure 5-37.

    Figure 5-37 Installing an AC power module

  7. Wait about one minute and check the status of the Running/Alarm indicator on the power module to determine whether the power module is successfully installed. Figure 5-38 shows the location of the Running/Alarm indicator.

    • If the indicator is steady green, the power module is successfully installed.
    • If the indicator is blinking green, the power module is incorrectly installed.
    • If the indicator is steady red or off, the newly installed power module is faulty or the power module slot is faulty.
    Figure 5-38 Running/Alarm indicator on a power module

  8. Confirm the replacement.

    After the preceding procedure is complete, check services on the host for any storage-related error. If any storage-related error is reported, contact Huawei technical support.

Follow-up Procedure