Parts Replacement

OceanStor V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, 6800F V5, 18500 V5, 18500F V5, 18800 V5, and 18800F V5. This document describes the procedure for replacing the parts of storage system in terms of safety operations, preparations, and precautions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Distinguishing CRUs and FRUs

Distinguishing CRUs and FRUs

This chapter describes how to replace customer replaceable units (CRUs) and field replaceable units (FRUs).

CRU

CRUs are components that users can replace at the deployment site by referring to the operation guide.

  • Operators: customers
  • Replaceable modules: power modules, BBU modules, and fan modules

Customers are allowed to replace CRUs, but are prohibited from replacing other components to prevent personal injury and device damage.

FRU

FRUs are components that engineers can replace at the deployment site by referring to the operation guide.

  • Operators: Huawei technical support engineers and maintenance engineers as well as technical support engineers and maintenance engineers certificated by Huawei
  • Replaceable modules: all replaceable modules

To effectively check software and hardware status and ensure the successful replacement of an FRU, use the FRU replacement tool of OceanStor SmartKit to guide you through the replacement. The FRUs that can be replaced using OceanStor SmartKit are listed in the FRU column in Table 3-1.

FRU and CRU List

Table 3-1 lists FRUs and CRUs.

Table 3-1 FRUs and CRUs

FRU

CRU

Power module

Power module

BBU

BBU

Fan module

Fan module

Controller

-

Interface module

-

System subrack

-

Disk module

-

Management module

-

Expansion module

-

Data switch

-

Optical module

-

Cable

-

Translation