No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Parts Replacement

OceanStor V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, 6800F V5, 18500 V5, 18500F V5, 18800 V5, and 18800F V5. This document describes the procedure for replacing the parts of storage system in terms of safety operations, preparations, and precautions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Replacing an Indicator Board (for 18000 V5/18000F V5 Series)

Replacing an Indicator Board (for 18000 V5/18000F V5 Series)

This section explains how to replace an indicator board.

Prerequisites

  • The spare part of the indicator board is ready.
  • The indicator board that you want to replace has been located. The cabinet door has one upper and one lower indicator boards, which can be replaced using the same method. This section shows how to replace an upper indicator board.

Precautions

Remove and insert the indicator board with even force. Excessive force may damage the appearance or connectors of the indicator board.

Tools and Materials

  • ESD wrist strap
  • ESD bag
  • Label
  • Phillips screwdriver

Procedure

  1. Wear an ESD wrist strap. Open the front cabinet door.
  2. Remove the indicator board to be replaced.

    1. Use a screwdriver to remove the screws of the indicator board's cover, slightly lift the cover, and then remove it, as shown in Figure 6-255.
      Figure 6-255 Removing the indicator board's cover

    2. Remove cables connected to the indicator board.
      NOTE:

      Two conversion cables need to be removed for an upper board. Two conversion cables and two input cables need to be removed for a lower board.

    3. Use a screwdriver to remove the screws of the indicator board and remove the board from the cabinet door.

  3. Install the indicator board.

    1. Take the replacement indicator board out of the ESD bag.
    2. Install the indicator board to the cabinet and fix it using screws.
    3. Connect cables.
    4. Install the indicator board's cover and fix it using screws.

  4. If the cabinet indicator is green, the indicator board is replaced successfully.

Follow-up Procedure

After the indicator board is replaced, label it for subsequent operations.