Parts Replacement

OceanStor V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, 6800F V5, 18500 V5, 18500F V5, 18800 V5, and 18800F V5. This document describes the procedure for replacing the parts of storage system in terms of safety operations, preparations, and precautions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Running/Alarm Indicators on Power Modules, BBUs, and Fan Modules

Running/Alarm Indicators on Power Modules, BBUs, and Fan Modules

After powering on a storage system, you can check the operating status of a power module, BBU, or fan module by viewing its indicators.

Running/Alarm Indicators on a 2 U Controller Enclosure

Figure 5-95 and Figure 5-96 show the indicators on the rear panel of a controller enclosure.

Figure 5-95 Indicators on the rear panel of a controller enclosure (for 5110 V5/5110F V5/5300 V5)
Figure 5-96 Indicators on the rear panel of a controller enclosure (for 5300F V5/5500 V5/5500F V5)

1

Running/Alarm indicator on a power module

2

Running/Alarm indicator on a BBU

Table 5-1 describes the indicators on the rear panel of a controller enclosure.

Table 5-1 Indicators on the rear panel of a controller enclosure

No.

Indicator

Status and Description

1

Running/Alarm indicator on a power module

  • Steady green: The power module is working properly.
  • Blinking green: The power input is normal but the device is powered off.
  • Steady red: The power module is faulty.
  • Off: No external power is input.

2

Running/Alarm indicator on a BBU

  • Steady green: The BBU is fully charged.
  • Blinking green (1 Hz): The BBU is being charged.
  • Blinking green (4 Hz): The BBU is being discharged.
  • Steady red: The BBU is faulty.

Running/Alarm Indicators on a 3 U Controller Enclosure

Figure 5-97 shows the indicators on the front panel of a controller enclosure.

Figure 5-97 Indicators on the front panel of a controller enclosure

1

Running/Alarm indicator on a BBU

2

Running/Alarm indicator on a fan module

Table 5-2 describes the indicators on the front panel of a controller enclosure.

Table 5-2 Indicators on the front panel of a controller enclosure

No.

Indicator

Status and Description

1

Running/Alarm indicator on a BBU

  • Steady green: The BBU is fully charged.
  • Blinking green (1 Hz): The BBU is being charged.
  • Blinking green (4 Hz): The BBU is being discharged.
  • Steady red: The BBU is faulty.

2

Running/Alarm indicator on a fan module

  • Steady green: The fan module is working properly.
  • Steady red: The fan module is faulty.
  • Off: The fan module is powered off.

Figure 5-98 shows the indicators on the rear panel of a controller enclosure.

Figure 5-98 Indicators on the rear panel of a controller enclosure

1

Running/Alarm indicator on a power module

-

-

Table 5-3 describes the indicators on the rear panel of a controller enclosure.

Table 5-3 Indicators on the rear panel of a controller enclosure

No.

Indicator

Status and Description

1

Running/Alarm indicator on a power module

  • Steady green: The power module is working properly.
  • Blinking green: The power input is normal but the device is powered off.
  • Steady red: The power module is faulty.
  • Off: No external power is input.

Running/Alarm Indicators on a 6 U Controller Enclosure

Figure 5-99 shows the indicators on the front panel of a controller enclosure.

Figure 5-99 Indicators on the front panel of a controller enclosure

1

Running/Alarm indicator on a BBU

2

Running/Alarm indicator on a fan module

Table 5-4 describes the indicators on the front panel of a controller enclosure.

Table 5-4 Indicators on the front panel of a controller enclosure

No.

Indicator

Status and Description

1

Running/Alarm indicator on a BBU

  • Steady green: The BBU is fully charged.
  • Blinking green (1 Hz): The BBU is being charged.
  • Blinking green (4 Hz): The BBU is being discharged.
  • Steady red: The BBU is faulty.

2

Running/Alarm indicator on a fan module

  • Steady green: The fan module is working properly.
  • Steady red: The fan module is faulty.
  • Off: The fan module is powered off.

Figure 5-100 shows the indicators on the rear panel of a controller enclosure.

Figure 5-100 Indicators on the rear panel of a controller enclosure

1

Running/Alarm indicator on a power module

-

-

Table 5-5 describes the indicators on the rear panel of a controller enclosure.

Table 5-5 Indicators on the rear panel of a controller enclosure

No.

Indicator

Status and Description

1

Running/Alarm indicator on a power module

  • Steady green: The power module is working properly.
  • Blinking green: The power input is normal but the device is powered off.
  • Steady red: The power module is faulty.
  • Off: No external power is input.

Running/Alarm Indicators on a Disk Enclosure

Figure 5-101 and Figure 5-102 show the indicators on the rear panel of a disk enclosure.

Figure 5-101 Indicators on the rear panel of a 2 U disk enclosure

Figure 5-102 Indicators on the rear panel of a 4 U disk enclosure

1

Running/Alarm indicator on a power/fan module

2

Running/Alarm indicator on a fan module

Table 5-6 describes the indicators on the rear panel of a disk enclosure.

Table 5-6 Indicators on the rear panel of a disk enclosure

No.

Indicator

Status and Description

1

Running/Alarm indicator on a power/fan module

  • Steady green: The power module and fan module are normal.
  • Blinking green: The power input is normal but the disk enclosure is powered off.
  • Steady red: The power module or fan module is faulty.
  • Off: No external power input is found.

2

Running/Alarm indicator on a fan module

  • Steady green: The fan module is working properly.
  • Steady red: The fan module is faulty.
  • Off: The fan module is powered off.

Running/Alarm Indicators on a High-Density Disk Enclosure

Figure 5-103 shows the indicators on the rear panel of a disk enclosure.

Figure 5-103 Indicators on the rear panel of a disk enclosure

1

Running/Alarm indicator on a power module

2

Running/Alarm indicator on a fan module

Table 5-7 describes the indicators on the front panel of a data switch.

Table 5-7 Indicators on the rear panel of a disk enclosure

No.

Indicator

Status and Description

1

Running/Alarm indicator on a power module

  • Steady green: The power module is working correctly.
  • Off: The power module is power off, or undervoltage, overvoltage, overtemperature, or short-circuit occurs.

2

Running/Alarm indicator on a fan module

  • Steady green: The fan module is working properly.
  • Steady red: The fan module is faulty.
  • Off: The fan module is powered off.
Translation
Download
Updated: 2019-07-11

Document ID: EDOC1000181634

Views: 46275

Downloads: 185

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next