No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Parts Replacement

OceanStor V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, 6800F V5, 18500 V5, 18500F V5, 18800 V5, and 18800F V5. This document describes the procedure for replacing the parts of storage system in terms of safety operations, preparations, and precautions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Replacing the Quorum Server

Replacing the Quorum Server

This section describes how to replace a quorum server.

Impact on the System

The services and programs running on the quorum server will be interrupted when it is removed. The arbitration mode of the active-active service automatically switches to the static priority arbitration mode.

Prerequisites

  • The spare part is ready.
  • You have determined the position of the quorum server for replacement.
  • All running services and programs on the quorum server are stopped, and the quorum server is powered off.
  • Data is backed up for the quorum server before it is removed.
  • The cable connection positions on the quorum server to be replaced are clearly marked.

Precautions

  • Remove or insert a quorum server with even force. Excessive force may damage the appearance or connectors of the quorum server.
  • The quorum server is heavy so that at least two persons are required to move it.

Tools and Materials

  • Electrostatic discharge (ESD) wrist strap or ESD gloves
  • Screwdriver

Procedure

  1. Power off the quorum server.
  2. Remove the quorum server.

    1. Disconnect all power cables and signal cables from the quorum server.
    2. Loosen the captive screws on the quorum server panel using a screwdriver. See step (1) in Figure 6-237.
      Figure 6-237 Removing the quorum server

    3. Pull out the quorum server along the guide rails away from the rack. See step (2) in Figure 6-237.
    4. Place the removed quorum server on the ESD platform for maintenance, for example, parts replacement.

  3. Reinstall the quorum server.

    1. At least two persons lift the quorum server on two sides and move it to the rack.
    2. Place the quorum server on the guide rails and push it into the rack, as shown in Figure 6-238.
      Figure 6-238 Installing the quorum server

    3. When the two mounting ears on the quorum server contact the mounting bars on the rack, tighten the captive screws on the mounting ears to secure the quorum server.

  4. Connect the cables and power on the quorum server.
  5. After the quorum server is powered on, reinstall and configure the quorum server software.

Follow-up Procedure

Log in to the quorum server, run the qsadmin command to go to the configuration page of the quorum server software, and run the show server_ip command to check whether the connection between the quorum server and storage devices is in Established state.

Q2qumrom:~ # qsadmin 
start main! 
Waiting for connecting to server... 
admin:/>show server_ip          
Index     Server IP           Server Port         
-----     ---------------     ---------------         
1         192.168.6.31        30002         
2         192.168.7.31        30002          
Index     Local IP            Local Port          Remote IP           Remote Port         State         
-----     ---------------     ---------------     ---------------     ---------------     ---------         
0         192.168.6.31        30002               192.168.6.17        44510             Established         
1         192.168.6.31        30002               192.168.6.18        36836             Established         
2         192.168.7.31        30002               192.168.7.16        57416             Established         
3         192.168.7.31        30002               192.168.7.28        49752             Established        
  • If yes, the quorum server is added successfully.
  • If no, the quorum server fails to be added. Check whether the IP address of the quorum server is correct.