This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, 6800F V5, 18500 V5, 18500F V5, 18800 V5, and 18800F V5. This document describes the procedure for replacing the parts of storage system in terms of safety operations, preparations, and precautions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Replacing a Disk Module

Replacing a Disk Module

This section describes how to replace a disk module.

Impact on the System

During the replacement of a disk module, if system reconstruction is complete, host services are not affected; if system reconstruction is not complete, the quorum server software may fail, and the arbitration mode of the active-active service will switch to the static priority arbitration mode.

Prerequisites

  • You have determined the position on the quorum server for removing a disk.
  • You have obtained the rack number and chassis number of the quorum server.
  • You have located the quorum server based on the preceding information, and labeled its panel to prevent misoperations.
  • The spare part is ready.

Tools and Materials

  • ESD gloves or ESD wrist strap
  • Packaging materials, for example, an ESD bag

Procedure

  1. Remove the disk.

    1. Push the spring that fastens the disk ejector lever. See step (1) in Figure 6-235.
      The ejector lever automatically ejects.
      Figure 6-235 Removing a disk

    2. Hold the ejector lever, and pull out the disk for about 3 cm (1.18 in.). See step (2) in Figure 6-235. Wait for at least 30 seconds until the disk stops working. Then remove the disk from the quorum server. See step (3) in Figure 6-235.
    3. Place the removed disk in an ESD bag.

  2. Install the disk.

    1. Take the spare disk out of the ESD bag.
    2. Fully raise the ejector lever and push the disk module into the chassis along the guide rails until it does not move. See step (1) in Figure 6-236.
      Figure 6-236 Installing a disk

    3. Ensure that the ejector lever is fastened to the chassis beam, and lower the ejector lever to completely insert the disk module into the chassis. See step (2) in Figure 6-236.

  3. Wait until the disk indicator turns normal, indicating that the disk is powered on.

Follow-up Procedure

Log in to the quorum server.

  1. Run the qsadmin command to check whether the configuration page of the quorum server software is displayed.
    Q2qumrom:~ # qsadmin 
    start main! 
    Waiting for connecting to server... 
    admin:/>
    • If the preceding command output is displayed, go to 2.
    • If the preceding command output is not displayed, the arbitration configuration information has been lost. In this case, reinstall and configure the quorum server software.
  2. Run the show server_ip command to check whether the connection between the quorum server and storage devices is in Established state.
    admin:/>show server_ip          
    Index     Server IP           Server Port         
    -----     ---------------     ---------------         
    1         192.168.6.31        30002         
    2         192.168.7.31        30002          
    Index     Local IP            Local Port          Remote IP           Remote Port         State         
    -----     ---------------     ---------------     ---------------     ---------------     ---------         
    0         192.168.6.31        30002               192.168.6.17        44510             Established         
    1         192.168.6.31        30002               192.168.6.18        36836             Established         
    2         192.168.7.31        30002               192.168.7.16        57416             Established         
    3         192.168.7.31        30002               192.168.7.28        49752             Established       
    • If yes, the quorum server can work properly.
    • If no, check whether the IP address of the quorum server is correct.
Translation
Download
Updated: 2019-07-11

Document ID: EDOC1000181634

Views: 46571

Downloads: 185

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next