No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

KunLun Mission Critical Server V100R001 SNMP Interface Description 09

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Function Description

Function Description

Simple node query and setting of the network table: allows users to query or set the IP address configuration mode, static IP address, floating IP address, static IP gateway, and floating IP gateway.

The table node OIDs are described as follows.

Node Name

Node OID Instance

Description

Type

Permission

cmcIpMode

1.3.6.1.4.1.2011.2.235.5.1.2.4.1

Queries or sets the IP mode.

static(1),

dhcp(2)

INTEGER

read-write

cmcStaticIpAddr

1.3.6.1.4.1.2011.2.235.5.1.2.4.2

Queries or sets the static IP address of the CMC.

Format: Ipaddress,Mask,BroadcastAddress

DisplayString

read-write

cmcFloatIpAddr

1.3.6.1.4.1.2011.2.235.5.1.2.4.3

Queries or sets the float IP address of the CMC.

Format:

Ipaddress,Mask,BroadcastAddress

DisplayString

read-write

cmcGatewayAddr

1.3.6.1.4.1.2011.2.235.5.1.2.4.4

Used to get or set the gateway of cmc.

format:

Gateway

DisplayString

read-write