Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Operating Temperature Limitations (Supercapacitor for the RAID Controller Card Configured)

Operating Temperature Limitations (Supercapacitor for the RAID Controller Card Configured)

Table A-2 Operating temperature specifications (with a RAID controller card supercapacitor configured)

Drive Backplane

Drive Quantity (Q)

CPU Power (P)

Maximum Temperature

X6000 V5 C00 24 NVMe backplane

16 < Q ≤ 24

P ≤ 165 W

30°C (86°F)

8 < Q ≤ 16

125 W ≤ P ≤ 165 W

30°C (86°F)

P < 125 W

35°C (95°F)

X6000 V5 C00 24 SAS backplane

16 < Q ≤ 24

125 W ≤ P ≤ 165 W

32°C (89.6°F)

P < 125 W

35°C (95°F)

8 < Q ≤ 16

140 W ≤ P ≤ 165 W

32°C (89.6°F)

P < 140 W

35°C (95°F)

0 < Q ≤ 8

P ≤ 165 W

35°C (95°F)

X6000 V5 C10 24 NVMe backplane

16 < Q ≤ 24

165 W < P ≤ 205 W

N/A

P ≤ 165 W

30°C (86°F)

8 < Q ≤ 16

165 W < P ≤ 205 W

N/A

125 W ≤ P ≤ 165 W

30°C (86°F)

P < 125 W

35°C (95°F)

0 < Q ≤ 8 (NVMe backplane not used)

/

/

X6000 V5 C10 24 SAS backplane

16 < Q ≤ 24

165 W < P ≤ 205 W

N/A

125 W ≤ P ≤ 165 W

32°C (89.6°F)

P < 125 W

35°C (95°F)

8 < Q ≤ 16

165 W < P ≤ 205 W

30°C (86°F)

140 W ≤ P ≤ 165 W

32°C (89.6°F)

P < 140 W

35°C (95°F)

0 < Q ≤ 8

165 W < P ≤ 205 W

32°C (89.6°F)

P ≤ 165 W

35°C (95°F)

X6000 V5 C10 12 x 3.5" SAS backplane

8 < Q ≤ 12

165 W < P ≤ 205 W

N/A

125 W ≤ P ≤ 165 W

32°C (89.6°F)

P < 125 W

35°C (95°F)

4 < Q ≤ 8

165 W < P ≤ 205 W

30°C (86°F)

140 W ≤ P ≤ 165 W

32°C (89.6°F)

P < 140 W

35°C (95°F)

0 < Q ≤ 4

165 W < P ≤ 205 W

32°C (89.6°F)

P ≤ 165 W

35°C (95°F)