Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing an M.2 FRU on the Avago SAS3004iMR PCIe RAID Controller Card

Installing an M.2 FRU on the Avago SAS3004iMR PCIe RAID Controller Card

The M.2 FRU on the Avago SAS3004iMR RAID controller card is hot swappable.

Procedure

  1. Determine the positions and slots of the M.2 FRUs on the Avago SAS3004iMR RAID controller card.

    Figure 8-29 Positions and slots of the M.2 FRUs

  2. Remove the M.2 FRU filler module.

    Perform this step only when you configure an M.2 FRU filler module.

  3. Install an M.2 FRU on the Avago SAS3004iMR PCIe RAID controller card.

    1. Take a spare M.2 FRU out of its ESD bag.
    2. Open the handle of the M.2 FRU and push the M.2 FRU into the slot of the Avago SAS3004iMR RAID control card. See (1) in Figure 8-30.
    3. Close the handle of the M.2 FRU. See (2) in Figure 8-30.
    Figure 8-30 Installing an M.2 FRU

  4. Check the status of the M.2 FRU indicator on the Avago SAS3004iMR RAID controller card.

    Figure 8-31 M.2 FRU indicators
    Table 8-2 Indicator status

    Indicator

    Description

    M.2 FRU fault indicator

    • Off: The M.2 FRU is running properly.
    • Blinking yellow: The M.2 FRU is being located, or RAID is being rebuilt.
    • Steady yellow: The M.2 FRU is faulty or not detected.

    M.2 FRU activity indicator

    • Off: The M.2 FRU is not in position or is faulty.
    • Blinking green: Data is being read, written, or synchronized.
    • Steady green: The M.2 FRU is inactive.