No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FusionServer Pro XH321 V5 Server Node V100R005 Maintenance and Service Guide 07

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Removing the Mainboard and Server Node Case

Removing the Mainboard and Server Node Case

Procedure

  1. Record the firmware (iBMC, BIOS, and CPLD) versions of the mainboard to be replaced.

    • On the iBMC WebUI, choose Information > System Info > Mainboard Info to obtain the information.
    • On the iBMC CLI, run the ipmcget -d version command to obtain the information.

  2. Check the iBMC and BIOS configurations.
  3. Export the iBMC or BIOS configuration files.

    For details, see iBMC WebUI > Configuration > Import/Export in FusionServer Pro X6000 Server iBMC User Guide.

    • The iBMC supports import and export of configuration files from version 2.32.
    • After replacing the mainboard, import the iBMC and BIOS configuration files that are exported from the iBMC. However, the exported configuration files do not contain password information. You need to manually configure the password for the iBMC user. For details, see iBMC WebUI > Configuration > Import/Export in FusionServer Pro X6000 Server iBMC User Guide.
    • The iBMC and BIOS configuration files exported from the iBMC contain the configuration list. For details, see "Configuration File Description" in FusionServer Pro X6000 Server iBMC User Guide.
    • If the iBMC of the mainboard to be replaced cannot be accessed or the iBMC and BIOS configuration files are not exported before the mainboard is replaced, manually configure the iBMC and BIOS data after replacing the mainboard.

  4. Power off the server node.

    For details, see Power-Off Procedure.

  5. Remove the server node.

    For details, see Removing an XH321 V5.

  6. Place the server node on the ESD workstation.
  7. Remove the air duct.

    For details, see Removing the Air Duct.

  8. Determine the position of the mainboard and the server node case.

    Figure 8-67 Mainboard and server node case

    The mainboard is packed in the server node case and replaced as a whole package.

  9. Remove the supercapacitor if there is any.

    For details, see Removing the Supercapacitor.

  10. Remove the screw-in RAID controller card.

    For details, see Removing the Screw-in RAID Controller Card.

  11. Remove the PCIe riser modules.

    For details, see Removing the PCIe Riser Module.

  12. Remove the TPM.

    For details, see Removing the TPM.

  13. Remove memory modules.

    For details, see Removing a Memory Module.

  14. Remove processors.

    For details, see Removing a Processor.

  15. Remove all cables from the mainboard.

    For details, see Internal Cabling.

  16. Place the removed server node case (with the mainboard) and components in different ESD bags.

    Before placing the mainboard and the server node case into an ESD bag, ensure that the processor sockets are installed with covers.

Download