Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing a C36 Node

Installing a C36 Node

Install a C36 node into the cabinet. If disks are not installed in the C36 node, insert disks into the C36 node.

Prerequisites

  • Operations described in Installing a Cabinet or Checking a Third-Party Cabinet have been completed.
  • Guide rails have been installed.
  • All required tools have been prepared, containing M3 to M6 Phillips screwdrivers, M6 screws, and protective gloves.

Context

  • A fully configured C36 node weighs up to 70 kg. Therefore, arrange for at least four persons to carry it and ensure that they wear protective gloves to avoid personal injury.
  • Install components into a cabinet from bottom to top to prevent the cabinet from falling over.

Procedure

  1. Install the C36 node into the cabinet.
    1. Wear the protective gloves.
    2. Slide the C36 node along the guide rail into the cabinet.
    3. Insert the screw into the floating nut through the screw hole on the C36 node and fasten the screw, as shown in Figure 8-67.

      Figure 8-67  Installing a C36 node

    4. Ensure that the C36 node sits properly and all bolts are fastened.

    NOTE:

    If disks have not been installed into the storage nodes, install the disks after installing the storage nodes. If disks have been installed into the storage nodes, skip step 2.

  2. Optional: Install service disks.

    One SSD and 35 SATA disks are configured for the C36 node. The SSD is installed in slot 0 in the upper left corner of the front panel.

    1. Wear ESD gloves.
    2. Take the disks to be installed out of the ESD bag.
    3. Raise the handle of the disk completely and push the disk straight into the slot with an appropriate amount of force, as shown in step 1 in Figure 8-68.

      • If the handle of the disk is not fully open, the disk cannot be completely inserted into the slot.
      • Excessive force may damage the disk connector.
      • To ensure favorable heat dissipation, insert disks in the sequence of disk slot IDs. If the disk module or PCIe module is not fully configured, cover filler panels over vacant disk slots or PCIe slots.
      Figure 8-68  Installing a disk

      The disk slots on the front panel of a C36 are numbered from 0 to 23 from left to right and from top to bottom, as shown in Figure 8-69.
      Figure 8-69  Disk slots on the front panel of a C36

      The disk slots on the rear panel of a C36 are numbered from 24 to 35 from left to right and from top to bottom, as shown in Figure 8-70.
      Figure 8-70  Disk slots on the rear panel of a C36

    4. Close the handle, as shown in step 2 in Figure 8-68.