No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OceanStor 9000 V300R006C20 Hardware Installation Guide 05

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing a P36 Node

Installing a P36 Node

Install a P36 node into the cabinet. If disks are not installed in the P36 node, insert disks into the P36 node.

Prerequisites

  • Operations described in Installing a Cabinet or Checking a Third-Party Cabinet have been completed.
  • Guide rails and floating nuts have been installed.
  • All required tools have been prepared, containing M3 to M6 Phillips screwdrivers, M6 screws, and protective gloves.

Context

  • A fully configured P36 node weighs up to 70 kg. Therefore, arrange for at least four persons to carry it and ensure that they wear protective gloves to avoid personal injury.
  • Install components into a cabinet from bottom to top to prevent the cabinet from falling over.

Procedure

  1. Install the P36 node into the cabinet.
    1. Wear the protective gloves.
    2. Slide the P36 node along the guide rail into the cabinet.
    3. Insert the screw into the floating nut through the screw hole on the P36 node and fasten the screw, as shown in Figure 8-63.

      Figure 8-63  Installing a P36 node

    4. Ensure that the P36 node sits properly and all bolts are fastened.

    NOTE:

    If disks have not been installed into the storage nodes, install the disks after installing the storage nodes. If disks have been installed into the storage nodes, skip step 2.

  2. Optional: Install service disks.

    One SSD and 35 SATA disks are configured for the P36 node. The SSD is installed in slot 0 in the upper left corner of the front panel.

    1. Wear ESD gloves.
    2. Take the disks to be installed out of the ESD bag.
    3. Raise the handle of the disk completely and push the disk straight into the slot with an appropriate amount of force, as shown in step 1 in Figure 8-64.

      • If the handle of the disk is not fully open, the disk cannot be completely inserted into the slot.
      • Excessive force may damage the disk connector.
      • To ensure favorable heat dissipation, insert disks in the sequence of disk slot IDs. If the disk module or PCIe module is not fully configured, cover filler panels over vacant disk slots or PCIe slots.
      Figure 8-64  Installing a disk

      The disk slots on the front panel of a P36 are numbered from 0 to 23 from left to right and from top to bottom, as shown in Figure 8-65.
      Figure 8-65  Disk slots on the front panel of a P36

      The disk slots on the rear panel of a P36 are numbered from 24 to 35 from left to right and from top to bottom, as shown in Figure 8-66.
      Figure 8-66  Disk slots on the rear panel of a P36

    4. Close the handle, as shown in step 2 in Figure 8-64.
Translation
Download
Updated: 2019-03-26

Document ID: EDOC1000185366

Views: 43492

Downloads: 162

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next