Server with 24 x 2.5" (16 x SAS/SATA + 8 x NVMe) Drivers
VGA Board Cabling
No. |
Huawei BOM Code |
Description |
---|---|---|
1 |
04051924 |
Signal cable for connecting the VGA board to the mainboard |
Left and Right Mounting Ear Cabling
No. |
Huawei BOM Code |
Description |
---|---|---|
1 |
04051922 |
Signal cable for connecting the indicator board of the right mounting ear to the mainboard |
2 |
04051921-001 |
Signal cable for connecting the USB board of the left mounting ear to the mainboard |
Drive Backplane Power Cabling
No. |
Huawei BOM Code |
Description |
---|---|---|
1 |
04152142 |
Power cable for connecting the drive backplane to the mainboard |
Drive Backplane Signal Cabling
No. |
Huawei BOM Code |
Description |
---|---|---|
1 |
04052010 |
Indicator signal cable for connecting the drive backplane to the mainboard |
NVMe SSD Adapter Cabling
No. |
Huawei BOM Code |
Description |
Corresponding Slot Number of the NVMe PCIe SSD |
---|---|---|---|
1 |
04051918-002 |
SAS cable for connecting the NVMe SSD adapter to the drive backplane (PORT 0-PORT B_N0) |
20 |
2 |
04051918-002 |
SAS cable for connecting the NVMe SSD adapter to the drive backplane (PORT 1-PORT B_N1) |
21 |
3 |
04051918-002 |
SAS cable for connecting the NVMe SSD adapter to the drive backplane (PORT 2-PORT B_N2) |
22 |
4 |
04051918-002 |
SAS cable for connecting the NVMe SSD adapter to the drive backplane (PORT 3-PORT B_N3) |
23 |
The NVMe SSD adapter can be installed only in slot 5.
No. |
Huawei BOM Code |
Description |
Corresponding Slot Number of the NVMe PCIe SSD |
---|---|---|---|
1 |
04051918-001 |
SAS cable for connecting the NVMe SSD adapter to the drive backplane (PORT 0-PORT A_N0) |
0 |
2 |
04051918-001 |
SAS cable for connecting the NVMe SSD adapter to the drive backplane (PORT 1-PORT A_N1) |
1 |
3 |
04051918-001 |
SAS cable for connecting the NVMe SSD adapter to the drive backplane (PORT 2-PORT A_N2) |
2 |
4 |
04051918-001 |
SAS cable for connecting the NVMe SSD adapter to the drive backplane (PORT 3-PORT A_N3) |
3 |
The NVMe SSD adapter can be installed only in slot 10.
PCIe RAID Controller Card Cabling
No. |
Huawei BOM Code |
Description |
---|---|---|
1 |
04051021 |
SAS cable for connecting PORT C_0 of the drive backplane to PORT A of the PCIe RAID controller card |
2 |
04051021 |
SAS cable for connecting PORT C_1 of the drive backplane to PORT B of the PCIe RAID controller card |
- The PCIe RAID controller card can be installed only in slot 4.
- When a Broadcom MegaRAID 9361-8i RAID controller card is used, the upper port corresponds to PORT C_0 of the drive backplane, and the lower port corresponds to PORT C_1 of the drive backplane.
Supercapacitor Cabling
No. |
Huawei BOM Code |
Description |
---|---|---|
1 |
N/A (the cable is delivered with the supercapacitor) |
Cable for connecting the PCIe RAID controller card to the supercapacitor |
USB 3.0 Port Cabling
No. |
Huawei BOM Code |
Description |
---|---|---|
1 |
04051947-001 |
Signal cable for connecting USB 3.0 port on the front panel to the mainboard |