Alarm Handling
CloudEngine 12800 and 12800E V200R003C00

This document provides the explanations, causes, and recommended actions of alarms on the product.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.6.5 hwFanInvalid

DEVM_1.3.6.1.4.1.2011.5.25.219.2.6.5 hwFanInvalid

Description

A fan module experienced a complete failure. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

The fan module failed.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwFanInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.6.5

Alarm ID

0x08130017

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.6.6 hwFanInvalidResume

Parameters

Name Meaning
EntPhysicalIndex Indicates the entity index.
EntPhysicalName Indicates the name of an entity.
EntityTrapFaultID Indicates the error code.
  • 139269
  • 137216
Reason Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

A fault of the fan module affects heat dissipation performance of the switch and increases the temperature of the switch. Services are not affected in a short time, but the fault should be rectified quickly.

Possible Causes

Cause 1 (EntityTrapFaultID=[139269]): Fan communicate with CMU is failed.

Cause 2 (EntityTrapFaultID=[137216]): The fan was not present.

Procedure

  • Cause 1: Fan communicate with CMU is failed.

    Collect traps, logs, and configurations, and contact technical support personnel.

  • Cause 2: The fan was not present.

    Install the fan properly.