Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Outbound/Inbound Bandwidth Usage Alarm Threshold

Configuring the Outbound/Inbound Bandwidth Usage Alarm Threshold

Context

The bandwidth usage represents the load on a device. If the bandwidth usage exceeds the threshold, bandwidth on the device is not sufficient for services and needs expansion. For example, if the bandwidth usage exceeds 95%, an alarm is generated to indicate that bandwidth resources are used up. Services may be interrupted before system expansion. You can expand device capacity to prevent service interruption.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The interface view is displayed.

  3. Run trap-threshold { input-rate | output-rate } bandwidth-in-use [ resume-rate resume-threshold ]

    The alarm threshold for the inbound/outbound bandwidth usage is configured for the interface.

    By default, the alarm thresholds of the outbound and inbound bandwidth usage are both 90.

    NOTE:

    If the difference between the bandwidth-in-use and resume-threshold values is too small, alarms may be frequently generated or cleared.

  4. Run commit

    The configuration is committed.