Configuration Guide - VXLAN

CloudEngine 12800 and 12800E V200R003C00

This document describes the configurations of VXLAN.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Verifying the VXLAN Configuration in Centralized Gateway Mode for Static Tunnel Establishment

Verifying the VXLAN Configuration in Centralized Gateway Mode for Static Tunnel Establishment

After configuring VXLAN in centralized gateway mode for static tunnel establishment, check VXLAN tunnel, VNI, and VBDIF interface information.

Prerequisites

VXLAN in centralized gateway mode has been configured for static tunnel establishment.

Procedure

  • Run the display bridge-domain [ bd-id [ brief | verbose ] ] command to check bridge domain configurations.
  • Run the display interface nve [ nve-number | main ] command to check NVE interface information.
  • Run the display vxlan peer [ vni vni-id ] command to check ingress replication lists of a VNI or all VNIs.
  • Run the display vxlan tunnel [ tunnel-id ] [ verbose ] command to check VXLAN tunnel information.
  • Run the display vxlan vni [ vni-id [ verbose ] ] command to check VNI information.
  • Run the display interface vbdif [ bd-id ] command to check VBDIF interface information and statistics.
  • Run the display dfs-group dfs-group-id active-active-gateway command to check information of all-active gateways in a DFS group.
  • Run the display arp broadcast-suppress user bridge-domain bd-id command to check the ARP broadcast suppression table of a BD.
  • Run the display arp [ network network-address [ network-mask | mask-length ] ] static command to check static ARP entries.
  • Run the display mac-address static bridge-domain bd-id command to check static MAC address entries in a BD.
  • Run the display mac-address limit bridge-domain bd-id command to check dynamically learning MAC address limiting configurations of a BD.
  • Run the display mac-address flapping command to check the MAC address flapping detection configuration.
  • Run the display vxlan flood-vtep [ vni vni-id ] command to check the VXLAN centralized replication list.