No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - VXLAN

CloudEngine 12800 and 12800E V200R003C00

This document describes the configurations of VXLAN.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Verifying the Configuration of VXLAN in Centralized Gateway Mode Using BGP EVPN

Verifying the Configuration of VXLAN in Centralized Gateway Mode Using BGP EVPN

After configuring VXLAN in centralized gateway mode for dynamic tunnel establishment, check VXLAN tunnel, VNI, and VBDIF interface information.

Prerequisites

VXLAN in centralized gateway mode has been configured for dynamic tunnel establishment.

Procedure

  • Run the display bridge-domain [ bd-id [ brief | verbose ] ] command to check bridge domain configurations.
  • Run the display interface nve [ nve-number | main ] command to check NVE interface information.
  • Run the display evpn vpn-instance [ name vpn-instance-name ] command to check EVPN instance information.
  • Run the display bgp [ instance instance-name ] evpn peer [ [ ipv4-address ] verbose ] command to check BGP EVPN peer information.
  • Run the display vxlan peer [ vni vni-id ] command to check ingress replication lists of a VNI or all VNIs.
  • Run the display vxlan tunnel [ tunnel-id ] [ verbose ] command to check VXLAN tunnel information.
  • Run the display vxlan vni [ vni-id [ verbose ] ] command to check VNI information.
  • Run the display interface vbdif [ bd-id ] command to check VBDIF interface information and statistics.
  • Run the display dfs-group dfs-group-id active-active-gateway command to check information of all-active gateways in a DFS group.
  • Run the display arp broadcast-suppress user bridge-domain bd-id command to check the ARP broadcast suppression table of a BD.
  • Run the display arp [ network network-address [ network-mask | mask-length ] ] static command to check static ARP entries.
  • Run the display mac-address static bridge-domain bd-id command to check static MAC address entries in a BD.
  • Run the display mac-limit bridge-domain bd-id command to check dynamically learning MAC address limiting configurations of a BD.
  • Run the display mac-address flapping command to check the MAC address flapping detection configuration.
  • Run the display bgp [ instance instance-name ] evpn all routing-table command to check EVPN route information.
  • Run the display mac-address inactive [ evn ] [ slot slot-id ] command to check the MAC address entries that fail to be delivered.
  • Run the display mac-address total-number evn [ vlan vlan-id ] command to check the number of EVN MAC address entries.
  • Run the display mac-address evn [ vlan vlan-id ] [ verbose ] command to check EVN MAC address entries.
  • Run the display vxlan flood-vtep [ vni vni-id ] command to check the VXLAN centralized replication list.
Translation
Download
Updated: 2019-05-05

Document ID: EDOC1100004207

Views: 30173

Downloads: 66

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next