Configuration Guide - DCN and Server Management

CloudEngine 8800, 7800, 6800, and 5800 V200R003C00

This document describes the configurations of Trill, FCoE, DCB, and NLB Server Cluster Association.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring a Zone

Configuring a Zone

Context

On a Fibre Channel over Ethernet (FCoE) network, communication between ENodes can be controlled using zones to improve the network security.

A zone contains multiple members, and an ENode can join different zones. Members in the same zone can communicate with each other, whereas members in different zones cannot.

A zone set contains multiple zones, each of which can join multiple zone sets. Zones in a zone set take effect only after the zone set is activated. Only one zone set can be activated at any given time in one instance.

A zone alias is used to simplify the zone configuration. When multiple member nodes need to be added to multiple zones, create a zone alias, associate the member nodes with the zone alias, and add the zone alias to the zones. In this case, you do not need to add each node to each zone one by one.

Procedure

  1. Run system-view

    The system view is displayed.

  2. (Optional) Run zone hard-zoning enable (Only CE6870EI and CE6875EI support this command)

    The hard zoning function is enabled.

    By default, the hard zoning function is disabled.

  3. (Optional) Run zone alias alias-name

    A zone alias is created and the zone alias view is displayed.

    By default, no zone alias is configured on the device.

  4. (Optional) Run member { fcid fc-id | interface { fcoe-port fcoe-port-id | fc fc-port-id } | wwnn wwnn | wwpn wwpn }

    A member node is associated with the zone alias.

    By default, no member node is associated with a zone alias.

  5. (Optional) Run quit

    Return to the system view.

  6. Run zone zone-name

    A zone is created and the zone view is displayed.

    By default, no zone is configured on the device.

  7. Run member { alias alias-name | fcid fc-id | interface { fcoe-port fcoe-port-id | fc fc-port-id } | wwnn wwnn [ auto | both | initiator | target ] | wwpn wwpn [ auto | both | initiator | target ] }

    A member node is added to the zone.

    By default, no member node is added to a zone.

  8. Run quit

    Return to the system view.

  9. Run zoneset zoneset-name

    A zone set is created and the zone set view is displayed.

    By default, no zone set is configured on the device.

  10. Run member zone-name

    The zone is added to the zone set.

    By default, no zone is added to a zone set.

  11. Run quit

    Return to the system view.

  12. Run fcoe fc-instance-name fcf

    The FCoE forwarder (FCF) instance view is displayed.

  13. (Optional) Run smart-zoning enable

    The Smart Zone function is enabled.

    By default, the Smart Zone function is disabled.

  14. Run active zoneset zoneset-name

    The zone set is activated.

    By default, no zone set is activated.

  15. Run commit

    The configuration is committed.