Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Example for Configuring the FCF and NPV (FCoE Interfaces)

Example for Configuring the FCF and NPV (FCoE Interfaces)

Networking Requirements

During deployment of a converged data center network, the access network convergence solution is used to protect investments on the existing storage area network (SAN) and NPVA and NPVB are used as the edge switch to expand the network scale, as shown in Figure 2-38. ServerA connects to NPVA and NPVB to constitute dual-plane networking, ensuring network reliability.

Figure 2-38 Networking of an FCF and an NPV switch
NOTE:
  • The device supports a maximum of 512 FCoE interfaces.

  • The CE7855EI, CE7850EI, CE6850HI, CE6856HI, CE6855HI, CE6851HI, and CE6850U-HI allow a maximum of 4096 VN_Ports to log in; the CE8860EI, CE8850EI, CE6860EI, and CE6850EI allow a maximum of 512 VN_Ports to log in; the CE6810EI allows a maximum of 256 VN_Ports to log in.

  • The device allows a maximum of 32 VN_Ports to be online concurrently in each zone.

Configuration Roadmap

The configuration roadmap is as follows:

  1. Create Fibre Channel over Ethernet (FCoE) interfaces on the FCF and NPV.

  2. On the FCF, create an FCoE forwarder (FCF) instance, specify an FCoE VLAN, and add an FCoE interface to the FCF instance.

  3. On the NPV, create an NPort Virtualization (NPV) instance, specify an FCoE VLAN and an NPV VLAN, and add FCoE interfaces to the NPV instance.

  4. On the FCF, add a physical interface to the FCoE interface and FCoE VLAN.

  5. On the NPV, add a physical interface to the FCoE interface, FCoE VLAN, and NPV VLAN.

  6. Configure the FCoE interface mapping on NPV.

  7. Configure a zone on the FCF and add ServerA and Array to the zone.

  8. Configure and activate a zone set on the FCF.

NOTE:

Configure Data Center Bridging (DCB). After DCB negotiation is successful, configure the FCF and NPV device.

Procedure

  1. Create FCoE interfaces.

    # Create FCoE-Port 1 and FCoE-Port 2 on FCFA.

    <HUAWEI> system-view
    [~HUAWEI] sysname FCFA
    [*HUAWEI] commit
    [~FCFA] interface fcoe-port 1
    [*FCFA-FCoE-Port1] quit
    [*FCFA] interface fcoe-port 2
    [*FCFA-FCoE-Port2] quit
    [*FCFA] commit
    

    # Create FCoE-Port 1 and FCoE-Port 2 on NPVA.

    <HUAWEI> system-view
    [~HUAWEI] sysname NPVA
    [*HUAWEI] commit
    [~NPVA] interface fcoe-port 1
    [*NPVA-FCoE-Port1] quit
    [*NPVA] interface fcoe-port 2
    [*NPVA-FCoE-Port2] quit
    [*NPVA] commit
    

  2. Create Fiber Channel (FC) instances.

    # Create an FC instance named fcf1 on FCFA, specify VLAN 2094 as the FCoE VLAN, and add FCoE-Port 1 and FCoE-Port 2 to fcf1.

    [~FCFA] fcoe fcf1 fcf
    [*FCFA-fcoe-fcf-fcf1] vlan 2094
    [*FCFA-fcoe-fcf-fcf1] member interface fcoe-port 1
    [*FCFA-fcoe-fcf-fcf1] member interface fcoe-port 2
    [*FCFA-fcoe-fcf-fcf1] quit
    [*FCFA] commit

    # Create an FC instance named npv1 on NPVA, specify VLAN 2093 as the FCoE VLAN and VLAN 2094 as the NPV VLAN, add FCoE-Port 1 and FCoE-Port 2 to npv1, and specify FCoE-Port 2 as the VN_Port.

    [~NPVA] fcoe npv1 npv
    [*NPVA-fcoe-npv-npv1] vlan 2093
    [*NPVA-fcoe-npv-npv1] npv-vlan 2094
    [*NPVA-fcoe-npv-npv1] member interface fcoe-port 1
    [*NPVA-fcoe-npv-npv1] member interface fcoe-port 2
    [*NPVA-fcoe-npv-npv1] fcoe role vn-port interface fcoe-port 2
    [*NPVA-fcoe-npv-npv1] quit
    [*NPVA] commit

  3. Configure a physical interface.

    # Configure 10GE1/0/1 on FCFA to allow VLAN 2094.

    [~FCFA] interface 10ge 1/0/1
    [~FCFA-10GE1/0/1] port link-type trunk
    [*FCFA-10GE1/0/1] port trunk allow-pass vlan 2094

    # Add 10GE1/0/1 on FCFA to FCoE-Port 1.

    [*FCFA-10GE1/0/1] fcoe-port 1
    [*FCFA-10GE1/0/1] quit
    [*FCFA] commit

    # Configure 10GE1/0/2 on FCFA to allow VLAN 2094.

    [~FCFA] interface 10ge 1/0/2
    [~FCFA-10GE1/0/2] port link-type trunk
    [*FCFA-10GE1/0/2] port trunk allow-pass vlan 2094

    # Add 10GE1/0/2 on FCFA to FCoE-Port 2.

    [*FCFA-10GE1/0/2] fcoe-port 2
    [*FCFA-10GE1/0/2] quit
    [*FCFA] commit

    # Configure 10GE1/0/1 on NPVA to allow VLAN 2093.

    [~NPVA] interface 10ge 1/0/1
    [~NPVA-10GE1/0/1] port link-type trunk
    [*NPVA-10GE1/0/1] port trunk allow-pass vlan 2093

    # Add 10GE1/0/1 on NPVA to FCoE-Port 1.

    [*NPVA-10GE1/0/1] fcoe-port 1
    [*NPVA-10GE1/0/1] quit
    [*NPVA] commit

    # Configure 10GE1/0/2 on NPVA to allow VLAN 2094.

    [~NPVA] interface 10ge 1/0/2
    [~NPVA-10GE1/0/2] port link-type trunk
    [*NPVA-10GE1/0/2] port trunk allow-pass vlan 2094

    # Add 10GE1/0/2 on NPVA to FCoE-Port 2.

    [*NPVA-10GE1/0/2] fcoe-port 2
    [*NPVA-10GE1/0/2] quit
    [*NPVA] commit

  4. Configure the FCoE interface mapping.

    # Configure the FCoE interface mapping on NPVA, and specify FCoE-Port 1 as the VF_Port and FCoE-Port 2 as the VN_Port.

    [~NPVA] fcoe npv1 npv
    [~NPVA-fcoe-npv1-npv] npv-map vf-port interface fcoe-port 1 vn-port fcoe-port 2
    [*NPVA-fcoe-npv1-npv] quit
    [*NPVA] commit

  5. Configure a zone.

    # Create a zone named Zone1 on FCFA and add ServerA and Array to Zone1. You can add member nodes to a zone using the WWPN, WWNN, FC_ID, and FCoE interface. The WWPN mode is recommended.

    [~FCFA] zone zone1
    [*FCFA-zone-zone1] member wwpn 30:00:00:68:50:40:30:01
    [*FCFA-zone-zone1] member wwpn 30:00:00:68:50:40:30:02
    [*FCFA-zone-zone1] quit
    [*FCFA] commit

  6. Configure and activate a zone set.

    # Create a zone set named Zoneset1 on FCFA and add Zone1 to Zoneset1.

    [~FCFA] zoneset zoneset1
    [*FCFA-zoneset-zoneset1] member zone1
    [*FCFA-zoneset-zoneset1] quit
    [*FCFA] commit

    # Activate Zoneset1 in the FCF instance fcf1.

    [~FCFA] fcoe fcf1 fcf
    [~FCFA-fcoe-fcf-fcf1] active zoneset zoneset1
    [*FCFA-fcoe-fcf-fcf1] quit
    [*FCFA] commit

  7. Verify the configuration.

    # Check registration information of the server and storage device.

    [~FCFA] display fcoe name-server brief
    The Name-Server Information:                                                    
    ------------------------------------------------------------------------------- 
    Interface           FC-ID             WWPN                                      
    ------------------------------------------------------------------------------- 
    FCoE1/0/1           16.00.01          30:00:00:68:50:40:30:01                   
    FCoE1/0/1           16.00.03          30:00:00:68:50:40:30:03                   
    FCoE1/0/2           16.00.02          30:00:00:68:50:40:30:02 
    ------------------------------------------------------------------------------- 
    Total: 2

    # Check the NPV instance information on NPVA.

    [~NPVA] display fcoe instance npv
    FCoE instance with NPV type:                                                    
    ------------------------------------------------------------------------------- 
    Instance name                   : npv1                                          
    VLAN                            : 2093                                          
    Instance MAC                    : 20:0b:c7:23:42:03                             
    FKA-ADV-Period(ms)              : 8000                                          
    Number of fcoe-port(VF)         : 1                                             
    Number of fcoe-port(VNP)        : 1                                             
    Number of online VF-Port        : 1                                             
    Number of online ENode VN-Port  : 1                                             
    ------------------------------------------------------------------------------- 
    Total: 1

  8. Configure FCFB and NPVB.

    Repeat steps 1 to 7 on FCFB and NPVB. For details, see the configuration files of FCFB and NPVB.

Configuration Files

  • Configuration file of FCFA

    #
    sysname FCFA
    #
    dcb pfc default
    #
    dcb ets-profile ets1                                                            
     priority-group 0 queue 0 to 2 4 to 6                                           
     priority-group 15 queue 7                                                      
     priority-group 0 drr weight 60                                                 
     priority-group 1 drr weight 40                                                 
    #
    lldp enable
    #
    zone zone1                                                                      
     member wwpn 30:00:00:68:50:40:30:01
     member wwpn 30:00:00:68:50:40:30:02                                            
    #                                                                               
    zoneset zoneset1                                                                
     member zone1                                                                   
    #
    fcoe fcf1 fcf                                                                   
     vlan 2094                                                                      
     member interface FCoE-Port1                                                    
     member interface FCoE-Port2
     active zoneset zoneset1
    #
    interface 10GE1/0/1                                                             
     port link-type trunk                                                           
     port trunk allow-pass vlan 2094                                                
     fcoe-port 1                                                                    
     lldp tlv-enable dcbx
     dcb pfc enable mode auto
     dcb ets enable ets1
    #
    interface 10GE1/0/2                                                             
     port link-type trunk                                                           
     port trunk allow-pass vlan 2094                                                
     fcoe-port 2                                                                    
     lldp tlv-enable dcbx
     dcb pfc enable mode auto
     dcb ets enable ets1
    #
    interface FCoE-Port1                                                            
    #
    interface FCoE-Port2                                                            
    #
    return
  • Configuration file of NPVA

    #
    sysname NPVA
    #
    dcb pfc default
    #
    dcb ets-profile ets1                                                            
     priority-group 0 queue 0 to 2 4 to 6                                           
     priority-group 15 queue 7                                                      
     priority-group 0 drr weight 60                                                 
     priority-group 1 drr weight 40                                                 
    #
    lldp enable
    #
    fcoe npv1 npv 
     vlan 2093                                                                      
     npv-vlan 2094                                                                  
     member interface FCoE-Port1                                                    
     member interface FCoE-Port2                                                    
     fcoe role vn-port interface FCoE-Port2                                         
     npv-map vf-port interface FCoE-Port1 vn-port FCoE-Port2                        
    #
    interface 10GE1/0/1                                                             
     port link-type trunk                                                           
     port trunk allow-pass vlan 2093                                                
     fcoe-port 1                                                                    
     lldp tlv-enable dcbx
     dcb pfc enable mode auto
     dcb ets enable ets1
    #
    interface 10GE1/0/2                                                             
     port link-type trunk                                                           
     port trunk allow-pass vlan 2094                                                
     fcoe-port 2                                                                    
     lldp tlv-enable dcbx
     dcb pfc enable mode auto
     dcb ets enable ets1
    #
    interface FCoE-Port1                                                            
    #
    interface FCoE-Port2                                                            
    #
    return
  • Configuration file of FCFB

    #
    sysname FCFB
    #
    dcb pfc default
    #
    dcb ets-profile ets1                                                            
     priority-group 0 queue 0 to 2 4 to 6                                           
     priority-group 15 queue 7                                                      
     priority-group 0 drr weight 60                                                 
     priority-group 1 drr weight 40                                                 
    #
    lldp enable
    #
    zone zone1                                                                      
     member wwpn 30:00:00:68:50:40:30:04
     member wwpn 30:00:00:68:50:40:30:05                                            
    #                                                                               
    zoneset zoneset1                                                                
     member zone1                                                                   
    #
    fcoe fcf1 fcf                                                                   
     vlan 2094                                                                      
     member interface FCoE-Port1                                                    
     member interface FCoE-Port2
     active zoneset zoneset1
    #
    interface 10GE1/0/1                                                             
     port link-type trunk                                                           
     port trunk allow-pass vlan 2094                                                
     fcoe-port 1                                                                    
     lldp tlv-enable dcbx
     dcb pfc enable mode auto
     dcb ets enable ets1
    #
    interface 10GE1/0/2                                                             
     port link-type trunk                                                           
     port trunk allow-pass vlan 2094                                                
     fcoe-port 2                                                                    
     lldp tlv-enable dcbx
     dcb pfc enable mode auto
     dcb ets enable ets1
    #
    interface FCoE-Port1                                                            
    #
    interface FCoE-Port2                                                            
    #
    return
  • Configuration file of NPVB

    #
    sysname NPVB
    #
    dcb pfc default
    #
    dcb ets-profile ets1                                                            
     priority-group 0 queue 0 to 2 4 to 6                                           
     priority-group 15 queue 7                                                      
     priority-group 0 drr weight 60                                                 
     priority-group 1 drr weight 40                                                 
    #
    lldp enable
    #
    fcoe npv1 npv 
     vlan 2093                                                                      
     npv-vlan 2094                                                                  
     member interface FCoE-Port1                                                    
     member interface FCoE-Port2                                                    
     fcoe role vn-port interface FCoE-Port2                                         
     npv-map vf-port interface FCoE-Port1 vn-port FCoE-Port2                        
    #
    interface 10GE1/0/1                                                             
     port link-type trunk                                                           
     port trunk allow-pass vlan 2093                                                
     fcoe-port 1                                                                    
     lldp tlv-enable dcbx
     dcb pfc enable mode auto
     dcb ets enable ets1
    #
    interface 10GE1/0/2                                                             
     port link-type trunk                                                           
     port trunk allow-pass vlan 2094                                                
     fcoe-port 2                                                                    
     lldp tlv-enable dcbx
     dcb pfc enable mode auto
     dcb ets enable ets1
    #
    interface FCoE-Port1                                                            
    #
    interface FCoE-Port2                                                            
    #
    return