No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Ethernet Switching

CloudEngine 8800, 7800, 6800, and 5800 V200R003C00

This document describes the configuration of Ethernet services, including configuring MAC address table, link aggregation, VLANs, MUX VLAN, Voice VLAN, VLAN mapping, QinQ, GVRP, VCMP, STP/RSTP/MSTP, VBST, SEP, RRPP, ERPS, LBDT, and Layer 2 protocol transparent transmission.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Configuring an Action to Perform After a Loopback Is Detected

(Optional) Configuring an Action to Perform After a Loopback Is Detected

Context

After loopback detection is enabled on an interface, the interface periodically sends detection packets and checks whether loopback packets are received. When a loopback is detected on an interface, the system sets the interface status to loopback, minimizing impact on the system and the entire network.

Procedure

  • Configuring an action to perform after a loopback is detected in the system view
    1. Run system-view

      The system view is displayed.

    2. Run loopback-detect action error-down

      The action to perform on the interface is set to error-down when a loopback is detected on the interface.

      The default action is alarm.

      When the system detects a loopback on an interface, the interface enters the Error-Down state and the system sends an alarm to the NMS.

      NOTE:

      If the action to perform on the interface is alarm, inter-device loopback may suppress loopback detection on other interfaces on the local device. In this situation, set the action to error-down or use STP to prevent loopback.

    3. Run commit

      The configuration is committed.

  • Configuring an action to perform after a loopback is detected in the interface view
    1. Run system-view

      The system view is displayed.

    2. Run interface interface-type interface-number

      The interface view is displayed.

    3. Run loopback-detect action { error-down | alarm }

      The action to perform on the interface is set when a loopback is detected on the interface.

      By default, when a loopback is detected on an interface, the action is as follows:
      • If the loopback-detect action error-down command is not used in the system view, an alarm is generated.
      • If the loopback-detect action error-down command is used in the system view, the interface is shut down.
      NOTE:

      If the loopback-detect action (interface view) and loopback-detect action error-down commands are executed in the interface view and system view respectively, the configuration in the interface view takes effect.

    4. Run commit

      The configuration is committed.

Follow-up Procedure

When the action is set to error-down, if a loopback occurs on the interface, the interface enters the Error-Down state. The device records the status of an interface as Error-Down when it detects that a fault occurs. The interface in Error-Down state cannot receive or send packets and the interface indicator is off. You can run the display error-down recovery command to check information about all interfaces in Error-Down state on the device.

When the interface is in Error-Down state, check the cause. You can use the following modes to restore the interface status:
  • Manual (after the interface enters the Error-Down state)

    When there are few interfaces in Error-Down state, you can run the shutdown and undo shutdown commands in the interface view or run the restart command to restore the interface.

  • Auto (before the interface enters the Error-Down state)

    If there are many interfaces in Error-Down state, the manual mode brings in heavy workload and the configuration of some interfaces may be ignored. To prevent this problem, run the error-down auto-recovery cause loopback-detect interval interval-value command in the system view to enable an interface in error-down state to go Up and set a recovery delay. You can run the display error-down recovery command to view automatic recovery information about the interface.

    NOTE:

    This mode is invalid for the interface that has entered the Error-Down state, and is only valid for the interface that enters the Error-Down state after the error-down auto-recovery cause loopback-detect interval interval-value command is used.