Configuration Guide - Reliability

CloudEngine 8800, 7800, 6800, and 5800 V200R003C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, EFM Configuration, and CFM Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling a Smart Link Group

Enabling a Smart Link Group

Context

After a Smart Link group is enabled, the slave interface in the group is blocked. After the Smart Link group is disabled, the blocked standby interface is restored.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run smart-link group group-id

    The Smart Link group view is displayed.

  3. Run smart-link enable

    The Smart Link group is enabled.

  4. Run commit

    The configuration is committed.