Configuration Guide - Reliability

CloudEngine 8800, 7800, 6800, and 5800 V200R003C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, EFM Configuration, and CFM Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling DLDP

Enabling DLDP

Context

Unidirectional links can be detected only when the devices on both ends of optical fibers or copper twisted pairs support DLDP functions.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run dldp enable

    DLDP is enabled globally.

    By default, DLDP is disabled globally and on each interface.

  3. Run interface interface-type interface-number

    The interface view is displayed.

    NOTE:

    DLDP cannot be configured on logical interfaces.

  4. Run dldp enable

    DLDP is enabled on the interfaces.

  5. Run commit

    The configuration is committed.