Configuration Guide - Reliability

CloudEngine 8800, 7800, 6800, and 5800 V200R003C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, EFM Configuration, and CFM Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Association Between CFM Modules

Configuring Association Between CFM Modules

Context

For details about principles and usage scenarios of association between CFM modules, see CFM Association.

Association between CFM modules is bidirectional. CFM modules report faults to each other.

You must perform operations on both CFM-enabled devices of a link.

Pre-configuration Tasks

Before configuring association between CFM modules, perform the operation of Configuring CC.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run oam-mgr

    The OAM management view is displayed.

  3. Configure unidirectional or bidirectional transmission of fault information between CFM modules. Select the configuration according to Table 7-23.

    Table 7-23 Association between CFM modules
    Scenario Configuration 1 Configuration 2

    Faults need to be transmitted bidirectionally between CFM modules.

    Run the oam-bind cfm md ma cfm md ma command to configure CFM modules to report faults to each other.

    NOTE:

    If the oam-bind cfm md ma cfm md ma command is used, two commands of oam-bind ingress cfm md ma egress cfm md ma in opposite directions will be displayed in the configuration file.

    Use the following commands:
    • Run the oam-bind ingress cfm md ma egress cfm md ma command to configure CFM for the link at one side of the device to report faults to CFM for the link at the other side of the device. ingress md md-name1 and ma ma-name1 specify the MD name and MA name of a link at one side of the device, respectively. egress md md-name2 and ma ma-name2 specify the MD name and MA name of a link at the other side of the device, respectively.

    • Run the oam-bind ingress cfm md ma egress cfm md ma command to configure CFM for the link at one side of the device to report faults to CFM for the link at the other side of the device. ingress md md-name1 and ma ma-name1 specify the MD name and MA name of a link at one side of the device, respectively. egress md md-name2 and ma ma-name2 specify the MD name and MA name of a link at the other side of the device, respectively.

    Faults need to be transmitted unidirectionally between CFM modules.

    Run either of the following commands based on the transmission direction:

    • Run the oam-bind ingress cfm md ma egress cfm md ma command to configure CFM for the link at one side of the device to report faults to CFM for the link at the other side of the device. ingress md md-name1 and ma ma-name1 specify the MD name and MA name of a link at one side of the device, respectively. egress md md-name2 and ma ma-name2 specify the MD name and MA name of a link at the other side of the device, respectively.

    • Run the oam-bind ingress cfm md ma egress cfm md ma command to configure CFM for the link at one side of the device to report faults to CFM for the link at the other side of the device. ingress md md-name1 and ma ma-name1 specify the MD name and MA name of a link at one side of the device, respectively. egress md md-name2 and ma ma-name2 specify the MD name and MA name of a link at the other side of the device, respectively.

    None

  4. Run commit

    The configuration is committed.