Configuration Guide - Reliability

CloudEngine 8800, 7800, 6800, and 5800 V200R003C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, EFM Configuration, and CFM Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Association Between CFM and an Interface

Configuring Association Between CFM and an Interface

Context

A device carrying IP services is usually dual-homed to an IP network to improve network robustness and service reliability. In Figure 7-19, CE1 connects to CE2 and CE4 through the active and standby links. To detect link connectivity, you can configure CFM between CE1 and CE4. When CFM detects a link fault, association between CFM and Port1 can be enabled so that other modules can detect the fault and services can be rapidly switched.

Figure 7-19 Association between CFM and an interface

For details about association between CFM and interfaces and usage scenarios, see CFM Association.

Pre-configuration Tasks

Before configuring association between CFM with an interface, perform the operation of Configuring CC.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The view of the interface at one end of the link is displayed.

  3. Run the following commands as required.

    • Run cfm md md-name ma ma-name remote-mep mep-id mep-id trigger if-down

      Association between CFM and an interface is configured and the MEP is configured to shut down and start the associated interface when detecting a fault.

      By default, association between CFM and an interface is not configured.

      If a MEP detects a connectivity fault between the MEP and a specified RMEP within the same MA, the MEP shuts down and then starts the associated interface after 7s.

    • Run cfm md md-name ma ma-name remote-mep mep-id mep-id trigger if-link-down

      Association between CFM and an interface is configured and the MEP is configured to shut down the associated interface when detecting a fault.

      By default, association between CFM and an interface is not configured.

      When the MEP in the specified MA detects a fault between itself and the RMEP, the MEP shuts down the associated interface.

      You can run the cfm trigger if-link-down command to associate CFM with an Eth-trunk member link.
      • When CFM detects a connectivity fault, the associated member link goes Down, service traffic except CFM traffic is blocked, and services on the faulty member link are switched to other member links.
      • When CFM detects that the faulty member link recovers, services are switched back to the member link.
    NOTE:

    The cfm trigger if-link-down and cfm trigger if-down commands are cannot be configured in the same interface view.

  4. Run commit

    The configuration is committed.