Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Optimizing Server Performance

Optimizing Server Performance

You can modify the SAS DM device scheduling policy to optimize the server performance.

  1. Run the cd /sys/block/dm-0/queue/ command to go to the queue directory.

    The DM devices dm-0 and dm-1 correspond to the LUNs created based on the SAS SSDs and must be changed based on the actual situation.
    HW00001: #cd /sys/block/dm-0/queue/

  2. Run the echo noop > scheduler command to modify the DM device scheduling policy.

    HW00001:/sys/block/dm-0/queue # echo noop > scheduler
    HW00001:/sys/block/dm-1/queue # echo noop > scheduler

  3. Add the following content to the /etc/rc.d/boot.local file:

    for sd in `ls -lha /dev/disk/by-id/scsi-hana* | awk -F '/' '{print $NF}'`; do echo noop > /sys/block/$sd/queue/scheduler; done