Setting Initialization Parameters
When starting the SmartLogger for the first time, set initialization parameters on the monitoring panel.
Context
If the SmartLogger is started for the first time, set the initialization parameters by referring to this section. If it is not started for the first time, it directly performs the automatic search and then the default page.
Procedure
- The following table describes the process for setting initialization
parameters. The parameter values in the following figures are for
reference only.
LCD
Operation Procedure
1. After startup, the SmartLogger enters the initialization page.
The default system language is English.
2. Press
to enter the Wizard page.
To return to the default page, press ESC. If some later re-settings are required, refer to Setting the System Language, Setting System Time Parameters, and Setting Communications Parameters.
3. Select a display language and then press
.
The pages will be displayed in the selected language.
4. Set the correct date and time and then press
.
- To select the specific parameter, press
. To set the parameter value, press
or
.
- The date and time are displayed in the formats of YYYY-MM-DD and hh:mm:ss respectively. YYYY stands for the year, MM the month, DD the date, hh the hour, mm the minute, and ss the second.NOTICE:
After the Time is successfully set, this time can be synchronized in all the inverters connected to the SmartLogger.
5. Set the Ethernet parameters and then press
.
6. Set the RS485 search address segment and then press
.
You need to set the search address segments for RS485-1, RS485-2, and RS485-3 respectively.
7. On the page, press
.
After the search is complete, the SmartLogger displays a search result. Press
to end this operation.
Visiting some menu requires identity authentication. Therefore, after you set the initialization parameters, change the password immediately to ensure the security of the user account. For details, see Change the Password.
- To select the specific parameter, press