FusionAccess V100R006C20 Alarm Handling 05 (FusionSphere 6.3.1)

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
1011001 Backup Server Not Configured

1011001 Backup Server Not Configured

Description

The alarm module checks whether the Backup Server is configured every 2 minutes. This alarm is generated if the Backup Server is not configured. This alarm is cleared when the Backup Server is configured and a scheduled backup task is created.

Attribute

Alarm ID

Alarm Severity

Auto Clear

1011001

Major

Yes

Parameters

Name

Meaning

Alarm ID

Identifies an alarm. Each alarm is uniquely identified by an alarm ID and an alarm name.

Alarm Severity

Indicates the severity of an alarm. Value:

  • Critical: indicates that a fault affecting services provided by the system occurs. You need to rectify the fault immediately. If a device or resource is faulty, rectify it immediately even if the fault occurs during non-working hours.
  • Major: indicates that a fault affecting the service quality of the system occurs. You need to rectify the fault immediately. If the service quality of a device or resource is degraded, rectify it immediately during working hours.
  • Minor: indicates a fault that does not affect service quality. To prevent more serious faults, this type of alarm needs to be observed or handled if necessary.
  • Warning: indicates a fault that may affect service quality. This type of alarm must be handled based on the error type.

Alarm Name

Identifies an alarm. Each alarm is uniquely identified by an alarm ID and an alarm name.

Object Type

Specifies the type of the object for which the alarm is generated.

Alarm Object Name

Specifies the name of the object for which the alarm is generated.

Component Type

(This parameter exists only in FusionManager.)

Specifies the type of the component for which the alarm is generated.

Generation Time

Specifies the time when the alarm is generated.

Clear Time

Specifies the time when the alarm is cleared.

Clear Mode

Specifies whether the alarm is manually or automatically cleared.

Operation

Specifies the operation that can be performed on the alarm.

Value: Manually Clear Alarm

Impact on the System

  • The current day backup data of the component for which the alarm is generated is lost and cannot be restored. The system reliability deteriorates.

Possible Causes

  • The Backup Server is not configured.

Procedure

  1. On FusionAccess > System > Other Configurations Protal.Enter the backup configuration information. click OK.The system displays a message indicating that the Backup Server is configured successfully and asks you to wait for 3 minutes.
  2. Choose FusionManager > Monitoring or FusionAccess > Alarm to check whether the alarm still exists.

    • If yes, contact Huawei technical support.
    • If no, no further operation is required.