No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FusionAccess V100R006C20 Alarm Handling 05 (FusionSphere 6.3.1)

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
1011004 No Third-Party FTP Backup Server Configured

1011004 No Third-Party FTP Backup Server Configured

Description

The alarm module checks backup servers every 2 minutes. This alarm is generated when the backup server configured on the ITA is not a third-party FTP backup server. This alarm is cleared when the backup server configuration is cleared or a third-party FTP backup server is configured.

Attribute

Alarm ID

Alarm Severity

Auto Clear

1011004

Major

Yes

Parameters

Name

Meaning

Alarm ID

Identifies an alarm. Each alarm is uniquely identified by an alarm ID and an alarm name.

Alarm Severity

Indicates the severity of an alarm. Value:

  • Critical: indicates that a fault affecting services provided by the system occurs. You need to rectify the fault immediately. If a device or resource is faulty, rectify it immediately even if the fault occurs during non-working hours.
  • Major: indicates that a fault affecting the service quality of the system occurs. You need to rectify the fault immediately. If the service quality of a device or resource is degraded, rectify it immediately during working hours.
  • Minor: indicates a fault that does not affect service quality. To prevent more serious faults, this type of alarm needs to be observed or handled if necessary.
  • Warning: indicates a fault that may affect service quality. This type of alarm must be handled based on the error type.

Alarm Name

Identifies an alarm. Each alarm is uniquely identified by an alarm ID and an alarm name.

Object Type

Specifies the type of the object for which the alarm is generated.

Alarm Object Name

Specifies the name of the object for which the alarm is generated.

Component Type

(This parameter exists only in FusionManager.)

Specifies the name of the component for which the alarm is generated.

Generation Time

Specifies the time when the alarm is generated.

Clear Time

Specifies the time when the alarm is cleared.

Clear Mode

Specifies whether the alarm is manually or automatically cleared.

Operation

Specifies the operation that can be performed on the alarm.

Value: Manually Clear Alarm

Impact on the System

  • If the CNA node or storage device where the Backup Server resides is faulty, the data backed up by the Backup Server may lose.

Possible Causes

  • The backup server configured on the ITA is not a third-party FTP backup server.

Procedure

  1. On FusionAccess, choose System > Other Configurations > Backup Server and configure a third-party FTP backup server.
  2. Wait for 2 minutes and choose FusionManager > Monitoring or FusionAccess > Alarm Monitoring to check whether the alarm still exists.

    • If yes, contact technical support.
    • If no, no further action is required.

Related Information

None

Download
Updated: 2019-03-01

Document ID: EDOC1100010511

Views: 19671

Downloads: 11

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next