No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

eSight V300R009C00 Local HA System Software Installation Guide (SUSE Linux + MySQL + OMMHA) 11

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Executing the Post-processing Script

Executing the Post-processing Script

This section describes how to execute the post-processing script to install eSight on the standby server and interconnect the active and standby eSight servers.

Procedure

  1. Use the PuTTY tool to log in to the active server as the root user.
  2. Run the following command to start the post-processing script:

    # cd /opt/install

    # chmod u+x install_post.sh

    # ./install_post.sh

    The process takes about 10 minutes.

    If information similar to the following is displayed, the post-processing script is successfully executed:

    begin to config local MySQL...  
    config MySQL finish.  
    buil credit... 
    buil credit finish 
    begin to rsync...  
    rsync finish.  
    begin to startup...  
    HAMode  
    double  
    
    NodeName   HostName     HAVersion    StartTime          HAActive   HAAllResOK     HARunPhase 
    ha1         Primaster  V100R001C01  2017-02-22 16:44:01 active       normal        Actived 
    ha2         Secmaster  V100R001C01  2017-02-22  16:46:45 standby      normal       Deactived 
    
    NodeName   ResName     ResStatus     ResHAStatus   ResType  
    ha1          MySQL     Active_normal   Normal    Active_standby  
    ha1         NMSServer     Normal       Normal    Single_active  
    ha1         RMFloatIp     Normal       Normal    Single_active  
    ha2           MySQL    Standby_normal  Normal    Active_standby  
    ha2         NMSServer    Stopped       Unknown   Single_active  
    ha2         RMFloatIp    Stopped       Normal    Single_active      

    Table 2-10 Two-node cluster resource status

    Resource Item

    Description

    Node

    Normal Status

    MySQL

    Database resource status.

    Active server

    Active_normal

    Standby server

    Standby_normal

    NMSServer

    eSight service resource status.

    Active server

    Normal

    Standby server

    Stopped

    RMFloatIp

    System floating IP address status.

    Active server

    Normal

    Standby server

    Stopped

  3. Delete the installation package and temporary files from the server after eSight is installed.

    # rm -rf /opt/install

Download
Updated: 2019-11-22

Document ID: EDOC1100011856

Views: 94752

Downloads: 54

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next