Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Adding a Single eLTE Device

Adding a Single eLTE Device

Before you manage eLTE devices using eSight, register and authenticate them.

Prerequisites

  • You have logged eSight client.
  • eSight eLTE Device Manager have been installed.
  • You have obtained the information of the device.
  • You have been assigned the operation rights.
  • You have been installed corresponding device adaptation package.
  • Before connecting Industry Terminals through the DNS, configure the DNS server. For details, see Software Installation Guide > Commissioning the eSight > Configuring System Services > Configuring Multi-Subnet Management.

Procedure

  • Adding a Single Customer Premises Equipment (Industry Terminal)
    1. Choose Resource > Common from the main menu.
    2. In the navigation tree in the left pane, choose Add Resource > Add Resource. The Add Resource page is displayed.
    3. Choose eLTE Device > Industry Terminal.
      NOTE:

      Choose Resource > eLTE > Resource Monitor > Industry Terminal from the main menu to enter the Industry Terminal page. Click Add Device in the toolbar to enter the Add Resource page.

    4. Enter Industry Terminal registration information.
      1. (Optional) Set Device Name.
      2. Set OUI and Serial Number.
      3. Set Subnet.
      4. (Optional) Set Location and Remark.
    5. Set Credential.
      1. Click Settings
      2. In the dialog box that is displayed, set authentication parameters.

        □ If Use default is set to Yes, the system uses the default user name and password as authentication credentials.

        □ If Use default is set to No, set NMS Authentication Information and Device Authentication Information.

        NOTE:

        To ensure system security, set Complexity check to On.

      3. Click OK.
    6. Click Apply.
      NOTE:

      If you want to register other Industry Terminals, repeat the preceding steps to specify the desired registration information on the current page. If you have finished Industry Terminal registration, click OK.

    7. Click Yes in the Confirm dialog box.
    8. Verify the Industry Terminal registration information.
      NOTE:
      • To be registered with eSight, the Industry Terminal must actively report messages.
      • During Industry Terminal reset, the Industry Terminal reports messages to eSight which then verifies Industry Terminal registration information.
      • In other scenarios, the Industry Terminal reports messages to eSight at a maximum interval of 24 hours.
      • In the Industry Terminal registration information list, if the management status of the Industry Terminal changes from Unregistered to Normal in the Management Status column, the Industry Terminal is successfully registered.
  • Add a single eNodeB device.
    1. Choose Resource > Common from the main menu.
    2. In the navigation tree in the left pane, choose Add Resource > Add Resource. The Add Resource page is displayed.
    3. Choose eLTE Device > eNodeB.
      NOTE:

      Choose Resource > eLTE > Resource Monitor > eNodeB from the main menu to enter the eNodeB page. Click Add in the toolbar to enter the Add Resource page.

    4. Enter eNodeB information.
      1. Enter IP address and Name and select Subnet and Device type in Basic Information.
      2. Optional: Set Location, Vendor, and Remark in Advanced Information.
    5. Click Apply.
      NOTE:

      If you want to register other devices, repeat the preceding steps to specify the desired registration information on the current page. If you have finished registration, click OK.

    6. Click Yes in the Confirm dialog box.
    7. Verify the eNodeB device registration information.
    8. If the adding is successful, eSight will initiate a connection to the eNodeB device. In the eNodeB device registration information list, if the management status of the device changes from Offline to Online in the Connection Status column, the eNodeB device is successfully registered.
  • Add a single core network device.
    1. Choose Resource > Common from the main menu.
    2. In the navigation tree in the left pane, choose Add Resource > Add Resource. The Add Resource page is displayed.
      Choose eLTE Device > eSE.
      NOTE:

      Choose Resource > eLTE > Resource Monitor > eSE from the main menu to enter the eSE page. Click Add in the toolbar to enter the Add Resource page.

    3. Enter core network information.
      • Enter IP address and Name and select Subnet and Device type in Basic Information.
      • Select Connection mode in Advanced Information.
      • Set Allow anonymous.

        If the version of eCNS610 is before V100R004C00, make sure this checkbox is selected.

        If the version of CGPOMU is before V200R016C10, make sure this checkbox is selected.

      • Optional: Set Geographical location, Vendor, and Remark.
      • If Device type is CGPOMU, set SNMP parameters.
        Table 18-4 SNMP information table

        Parameter Name

        Value Sample

        Description

        SNMP version

        V3

        Indicates that the SNMP user uses the SNMPv3 protocol that supports encryption.

        Security name

        v3User1

        Indicates the SNMP user name.

        Authentication password

        None

        Indicates the authentication password for login.

        NOTE:

        The password needs to be specified only when Authentication protocol is set to HMAC_SHA or HMAC_MD5.

        Privacy protocol

        None

        Indicates the encryption password for transmission.

        NOTE:

        The password needs to be specified only when Privacy protocol is set to AES_256, AES_128, or CBC_DES.

        Authentication protocol

        HMAC_SHA

        Indicates the SNMP user's authentication protocol.

        • HMAC_SHA: indicates that the HMAC-SHA-96 protocol is used to authenticate SNMP users.
        • HMAC_MD5: indicates that the HMAC-MD5-96 protocol is used to authenticate SNMP users.
        • None: indicates no authentication for SNMP users.

        Privacy protocol

        AES_256

        Indicates the encryption protocol.

        • AES_256: indicates that the AES-256 encryption protocol is used.
        • AES_128: indicates that the AES-128 encryption protocol is used.
        • CBC_DES: indicates that the CBC-DES encryption protocol is used.
        • None: indicates that no encryption protocol is used.

        Timeout interval

        120

        Indicates the SNMP timeout interval.

        NOTE:
        • The authentication protocols HMAC_SHA and HMAC_MD5 are not secure. It is recommended that you use AES_256 as the privacy protocol to enhance security.
        • The parameters specified must be the same as those on devices. Otherwise, the alarm function may fail.
        • You can log in to the device LMT and run the LST SNMPUSER MML command to query related information.
    4. Click Apply.
      NOTE:
      • If you want to register other devices, repeat the preceding steps to specify the desired registration information on the current page. If you have finished eSE device registration, click OK.
      • After the CGPOMU is added, eSight automatically adds the eCNS600 or ESS managed by the CGPOMU.
    5. Click Yes in the Confirm dialog box.
    6. Verify the registration information.

      If the adding is successful, eSight will initiate a connection to the eSE device. In the eSE device registration information list, if the management status of the eSE device changes from Offline to Online in the Connection Status column, the eSE device is successfully registered.

  • Add a single eNodeB device.
    1. Choose Resource > Common from the main menu.
    2. In the navigation tree in the left pane, choose Add Resource > Add Resource. The Add Resource page is displayed.
    3. Choose eLTE Device > eNodeB.
      NOTE:
      1. Choose Resource > eLTE > Resource Monitor > eNodeB from the main menu to enter the eNodeB page. Click Add in the toolbar to enter the Add Resource page.
    4. Enter eNodeB information.
      1. Enter IP address and Name and select Subnet and Device type in Basic Information.
      2. Optional: Set Location, Vendor, and Remark in Advanced Information.
    5. Click Apply.
      NOTE:
      1. If you want to register other devices, repeat the preceding steps to specify the desired registration information on the current page. If you have finished registration, click OK.
    6. Click Yes in the Confirm dialog box.
    7. Verify the eNodeB device registration information.
    8. If the adding is successful, eSight will initiate a connection to the eNodeB device. In the eNodeB device registration information list, if the management status of the device changes from Offline to Online in the Connection Status column, the eNodeB device is successfully registered.
  • Add a single eOMC device.
    1. Choose Resource > Common from the main menu.
    2. In the navigation tree in the left pane, choose Add Resource > Add Resource. The Add Resource page is displayed.

      Choose eLTE Device > eOMC.

    3. Enter eOMC information.
      • Enter IP address and Name and set Geographical location, Vendor, and Remark.and select Subnet and Device type in Basic Information.
      • Set SNMP parameters.
        Table 18-5 SNMP information table

        Parameter Name

        Value Sample

        Description

        SNMP version

        V3

        Indicates that the SNMP user uses the SNMPv3 protocol that supports encryption.

        Security name

        v3User1

        Indicates the SNMP user name.

        Authentication password

        None

        Indicates the authentication password for login.

        NOTE:

        The password needs to be specified only when Authentication protocol is set to HMAC_SHA or HMAC_MD5.

        Privacy protocol

        None

        Indicates the encryption password for transmission.

        NOTE:

        The password needs to be specified only when Privacy protocol is set to AES_256 or CBC_DES.

        Authentication protocol

        HMAC_SHA

        Indicates the SNMP user's authentication protocol.

        • HMAC_SHA: indicates that the HMAC-SHA-96 protocol is used to authenticate SNMP users.
        • HMAC_MD5: indicates that the HMAC-MD5-96 protocol is used to authenticate SNMP users.
        • None: indicates no authentication for SNMP users.

        Privacy protocol

        AES_256

        Indicates the encryption protocol.

        • AES_256: indicates that the AES-256 encryption protocol is used.
        • CBC_DES: indicates that the CBC-DES encryption protocol is used.
        • None: indicates that no encryption protocol is used.

        Timeout interval

        120

        Indicates the SNMP timeout interval.

        Retry time

        3

        Indicates the number of repeatable connections.

        NOTE:
        • If the SNMP authentication parameters are incorrectly filled in and the number of retries is more than 2 times, the eOMC will lock the eSight's IP address for a duration of 15 minutes.
        • The options of Authentication protocol are HMAC_SHA and HMAC_MD5. The security level of HMAC_SHA is higher than the security level of HMAC_MD5 but still cannot meet requirements of NIST specifications. Set Privacy protocol to AES_256 to enhance the security. It is recommended that the authentication password and privacy password are different.