Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Transmission Channel Management

Transmission Channel Management

Configuring the Communication Security Between Devices and the eSight Infrastructure Manager.

Setting In-band Transmission Parameters

This section describes how to set the in-band transmission parameters of a site. The eSight Infrastructure Manager supports both in-band and out-of-band data transmission modes. If the in-band transmission mode is used, you need to set in-band transmission parameters before creating a site.

Prerequisites

  • You have logged in to the eSight Infrastructure Manager client by web browser.
  • You are authorized to use Modify Infrastructure Right.
    The operation right consist of all operation rights for the following function menus:
    • Resource > Infrastructure > Configuration > Configuration Management > Data Center Planning
    • Resource > Infrastructure > Configuration > Configuration Management > Transmission Channel Management
  • Information about the base station type (GSM, UMTS or LTE) and its IP address at the site is available.
  • You have the operation rights for Transmission Channel Management.

Context

In-band transmission: Energy and environment data of a site is transmitted to the eSight Infrastructure Manager through the operation and maintenance (OM) channels of Huawei GBTSs or NodeBs/eNodeBs. The eSight Infrastructure Manager centrally manages the energy and environment devices based on the data. The GBTSs must be in GBSS12.0 or later versions and NodeBs must be in RAN13.0 or later versions.

Procedure

  1. Choose Resource > Infrastructure > Configuration > Configuration Management > Transmission Channel Management from the main menu. The Transmission Channel Management window is displayed.
  2. Click the Wireless Device Transparent Channel Settings tab in the displayed Transmission Channel Management window.
  3. Add an in-band transmission channel by referring to Figure 21-87 on the Wireless Device Transparent Channel Settings tab page. For details about related parameters, see Table 21-55.

    Figure 21-87 Add an in-band transmission channel

    If the site and eSight Infrastructure Manager can be properly connected after the in-band channel is created, the channel status icon is . Otherwise, the channel status icon is .

    Table 21-55 Parameter description

    Parameter

    Description

    Channel Name

    Name of a channel. You can set it as required.

    Channel IP

    IP address of a BSC or NodeB/eNodeB at a GSM or UMTS/LTE site, which is provided by operators.

    Channel Type

    Channel type. For a GSM site, the value is BSC. For a UMTS/LTE site, the value is NodeB/eNodeB.

    Connection Type

    Mode in which you connect a BSC or NodeB/eNodeB at a GSM or UMTS/LTE site to the eSight Infrastructure Manager. This parameter can be set to SSL or NORMAL.

Follow-up Procedure

You can perform the following operations after an in-band channel is created successfully.

If You Need To...

Then...

Search for in-band transmission channels

Set search criteria and click Search.

View channel data

On the Wireless Device Transparent Channel Settings tab page, view the existing in-band channels.

Modify channel data

  1. Change the values of channel parameters as required.
  2. Click Apply.
NOTE:
You can change the values of only Channel Name and Channel IP.

Delete channel data

  1. Delete channel data.

    Select the check boxes of the channel data records you want to delete. Click Delete and select Selected Channel.

  2. Click Yes.

Download channel data template

  1. Click Import.
  2. In the displayed Import Channel dialog box, click Download Template.
  3. In the displayed Download dialog box, click Save to save the template in the specified directory.

Import channel data

  1. Click Import.
  2. In the displayed Import Channel dialog box, click and select the directory of the file you want to import.
  3. Click Wireless Device Transparent Channel Settings.

A message is displayed after successful import. You can view the imported data on the Wireless Device Transparent Channel Settings tab page.

Export channel data

  1. Export channel data.
    • Export some channel data.

      Select the check boxes of the channel data records you want to export. Click Export and select Selected Channel to export the channel data in batches.

    • Export all channel data.

      Click Export and select All to export the channel data in batches.

  2. In the displayed Download dialog box, click Save to save the data in the specified directory.

View associated sites

Click Show Associated Site to view sites which communicate with eSight Infrastructure Manager through the channel.

Change the channel password

NOTE:

Only when a site associated with the channel supports the change of the channel password, Password Set is displayed in the password management column corresponding to the channel. Otherwise, the column is empty.

  1. Click Password Set corresponding to the channel whose password you want to change.
  2. In the Channel Password Set page, set Password, New Password, and Confirm Password, and click OK.
    NOTE:

    The preset password is ei*b+@b#6Nh(tS1j.

    You need to change the preset password in time and change it periodically (for example, every three months or six months) to ensure system security.

    Password last change time of user emscommneteco is displayed in the channel list of the Wireless Device Transparent Channel Settings tab page.

Change the channel password in batches

  1. Change the channel password in batches
    • Change some channel password.

      In the channel list of the Wireless Device Transparent Channel Settings tab page, select the channel whose password you want to change. Click BulkSet and select Selected Channel.

    • Change all channel password.

      Click BulkSet and select All.

  2. In the Channel Password Set page, set Password, New Password, and Confirm Password, and click OK.

Adding the Challenge Handshake Authentication for Modbus, Telecom and Access Control Protocol Devices Through the ECC

When the Modbus, Telcom and access control protocol devices access the eSight Infrastructure Manager through the ECC, you need to add the password of ECC challenge handshake authentication for the eSight Infrastructure Manager to ensure the validity of identity authentication between devices and the eSight Infrastructure Manager.

Prerequisites

  • You have logged in to the eSight Infrastructure Manager client by web browser.
  • You are authorized to use Modify Infrastructure Right.
    The operation right consist of all operation rights for the following function menus:
    • Resource > Infrastructure > Configuration > Configuration Management > Data Center Planning
    • Resource > Infrastructure > Configuration > Configuration Management > Transmission Channel Management

Procedure

  1. Choose Resource > Infrastructure > Configuration > Configuration Management > Transmission Channel Management from the main menu. The Transmission Channel Management window is displayed.
  2. Click the Energy Controller Transparent Channel Settings tab in the displayed Transmission Channel Management window.
  3. Click Refresh, all the ECC devices connected to the eSight Infrastructure Manager are displayed.

    Check whether the ECC supports the challenge handshake authentication.

    NOTE:
    Supports challenge handshake authentication ECC version is as follows:
    • ECC500 V600R001C01 or later
    • ECC800 V100R001C41SPC100 or later

  4. Select the ECC you want to configure. Click Modify and perform the following operations in the displayed dialog:

    • If the ECC does not supports challenge handshake authentication, select Compatible in the Connection Mode and click Confirm.
    • If the ECC supports challenge handshake authentication, select Security Protocol in the Connection Mode. Input the New Password and the Confirm Password and click Confirm.
      NOTE:
      • The network management parameters must be consistent with the Web side.

      • The password must meet the following complexity requirements:

        • The password contains 6 to 32 characters.
        • The password must contain at least one uppercase letter, one lowercase letter, and one digit.
        • The password cannot contain the comma (,).

  5. Restart the eSight Infrastructure Manager services.