Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Customizing a Monitoring View for a Large Screen

Customizing a Monitoring View for a Large Screen

This section describes how to customize a monitoring view for a large high-resolution screen to display services such as the topology of devices on the large screen. This function enables monitoring of key information using the large screen and display of the IT operation and maintenance effect.

Prerequisites

  • You have logged in to the eSight Infrastructure Manager client by web browser.
  • You are authorized to use View Infrastructure Right.
    The operation right consist of all operation rights for the following function menus:
    • Resource > Infrastructure > Monitor
    • Resource > Infrastructure > Alarm
    • Resource > Infrastructure > Business
    • Resource > Infrastructure > Analysis
    • Resource > Infrastructure > Configuration > Configuration Management > Access Control Management
    • Resource > Infrastructure > Configuration > Configuration Management > Device Software Management
    • Resource > Infrastructure > Configuration > Autocontrol > Autocontrol Strategy
    • Resource > Infrastructure > System

Context

  • The Big Screen Monitor function option is not displayed in the main menu by default. To display it in the main menu, you need to enable the function in the eSight Infrastructure Management Maintenance Tool. For details, see Configuring eSight Infrastructure Manager Menu Options in the eSight Product Documentation.

  • The eSight Infrastructure Manager supports a large high-resolution screen formed by only one screen (no border line) and a large screen formed by multiple split screens (there are border lines between split screens). For a large screen formed by multiple split screens, it is recommended that the number of split screens and the resolution of each split screen be set based on the actual screen conditions.
    • Set the screen resolution to the resolution of the large screen used for projection. The resolution is not affected by the number of split screens.
    • If the content needs to be projected onto one large screen, set the number of split screens to 1*1. If the content needs to be projected onto four split screens (the content on each split screen is different), set the number of split screens to 2*2. Set the number of split screens by following the preceding principles.
  • After you press F11 on the demonstration page, you can check the monitoring view in full-screen mode.

Procedure

  1. Choose Resource > Infrastructure > Monitor > Monitor Tools > Big Screen Monitor from the main menu. The Big Screen Monitor window is displayed.
  2. Customize a monitoring view for a large screen using either of the following methods:

    • Create and customize a monitoring view for a large screen.
      1. Click in the row of View.
      2. In the Create View dialog box, set the view name and add the monitoring views to display on the large screen.

        For the services that can be added to the portlet, see Table 21-26.

      3. Click Close.

        After creating a view, you can perform operations such as Remove, Rename, and Set as preferred view on the view.

        NOTE:

        The subsequently created home page supports First Custom View.

    • Customize the monitoring view for a large screen in an existing view.
      1. On the right side of the default view, click Customize.
      2. In the Customize View dialog box, add the monitoring views to display on the large screen.

        For the services that can be added to the portlet, see Table 21-26.

      3. Click Close.
    Table 21-26 Portlet description
    Portlet Description
    Topo

    Displays the topology of the management domain.

    On the right of Topo, click . You can perform the following operations in the Preview dialog box:
    • Select a management domain whose topology needs to be viewed.
      1. Click on the right.
      2. In the displayed Select Managed Domains dialog box, select a management domain.
      3. Click Confirm.
    • Optional: Set the management domain polling interval if multiple management domains are added.
      1. Click on the right.
      2. In the displayed Refresh Cycle Setting dialog box, enter a management domain polling interval.
        NOTE:

        The default interval is 1 minute and the allowed maximum value is 30 minutes.

      3. Click Confirm.
    Latest Alarms

    Displays the latest 10 active alarms. You can click the device name in the alarm source column to switch to the Current Alarms page for the corresponding device and alarm severity.

    NOTE:

    You can add this information segment only once on the corresponding home page.

    Alarms On Top N Devices

    Displays alarm statistics collected on the Current Alarms page for NEs or devices. You can click the number in the corresponding alarm severity column to switch to the Current Alarms page.

    On the right of Alarms On Top N Devices, click . In the displayed Preview dialog box, click and set Top N and Refresh interval (min) for alarm statistics collection.

    NOTE:

    You can add this information segment only once on the corresponding home page.

    Current Alarms

    Displays the number of current alarms for each severity. If you click a bar graph on the Preview page, the Current Alarms page for the corresponding alarm severity will be displayed. Then, you can view the alarm details.

    Capacity

    Displays real-time capacity data of different management domains.

    On the right of Capacity, click . In the displayed Preview dialog box, click , select a management domain, and click Confirm.

    NOTE:

    A subnet, park, building, service equipment room, and cabinet support this portlet.

    Energy Analyse

    Displays real-time power usage effectiveness (PUE) data.

    On the right of Energy Analyse, click . In the displayed Preview dialog box, click , select a management domain, and click Confirm.

    NOTE:

    PUE configuration must be completed for the selected management domain.

    After a management domain is selected, you can click to edit the title name.

    PUE Change

    Displays PUE trends.

    On the right of PUE Change, click . In the displayed Preview dialog box, click , select a management domain, and click Confirm.

    NOTE:

    PUE configuration must be completed for the selected management domain.

    Power Consumption Curve

    Displays the power consumption trend of the management domain in the last 30 days.

    On the right of Power Consumption Curve, click . In the displayed Preview dialog box, click , select a management domain, and click Confirm.

    NOTE:

    PUE configuration must be completed for the selected management domain.

    Day Power Consumption

    Displays the total power consumption and power consumption of IT equipment on the current day.

    On the right of Day Power Consumption, click . In the displayed Preview dialog box, click , select a management domain, and click Confirm.

    NOTE:

    PUE configuration must be completed for the selected management domain.

    NOTE:

    In the Preview dialog box of each portlets, you can click to refresh the information.

  3. Click Save.
  4. To display the current view in full screen, click Show.

Follow-up Procedure

You can perform the following operations in the added portlets.

If You Need To...

Then...

Delete the portlet.

  1. Click in the upper right of the portlet.
  2. In the displayed dialog box, click Yes.

Adjust the portlet.

  • Adjust the position of the portlet: Drag the portlet to the target position.
  • Adjust the size of the portlet: Place the cursor on any border line of the portlet and press the mouse to set the portlet size to an appropriate value.