Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Adding a Single CSP

Adding a Single CSP

You can add CSP (Content Storage Platform), on the eSight one by one.

Prerequisite

CSP protocol parameters have been set. For the detailed operation procedure, see the related document of the CSP.

Procedure

  1. Choose Resource > Common from the main menu. In the navigation tree on the left, select Add Resource > Add Resource.

  2. Click Intelligent Video Surveillance > CSP.
  3. Set CSP parameters according to Table 15-4.

    NOTE:

    To obtain the SNMP parameters of the CSP device, perform the following operations:

    1. Log in to the CSP device portal.
    2. Choose System > SNMP Management from the main menu.
    3. View SNMP parameters on the right of the page.
    Table 15-4 Parameter description

    Parameter

    Description

    Setting

    Basic Information

    Name

    Name of the device.

    N/A

    SNMP

    IP address

    IP address of the CSP server.

    Set this parameter to the physical IP address of the Outer-OM network plane of the CSP01 or CSP02 node.

    Port

    Port that the CSP uses to receive requests from the eSight.

    The default value is 8000.

    Set this parameter to the value of Port that is set on the CSP.

    Security name

    User security name.

    Set this parameter to the value of Security name that is set on the CSP.

    Context name

    Name of the subset for the managed objects.

    Set this parameter to the value of Context name that is set on the CSP.

    Authentication protocol

    Algorithm that the CSP uses to authenticate the eSight.

    Set this parameter to the value of Authentication protocol that is set on the CSP.

    The default value is HMAC_SHA.

    Authentication key

    Password that the CSP uses to authenticate the eSight.

    Set this parameter to the value of Authentication key that is set on the CSP.

    The default password is r1+@z(9Ho3b.

    Privacy protocol

    Algorithm used for data encryption during the communication between the eSight and the CSP.

    Set this parameter to the value of Privacy protocol that is set on the CSP.

    The default value is AES_128.

    Privacy key

    Password that the eSight uses to parse the encrypted data when communicating with the CSP.

    Set this parameter to the value of Privacy key that is set on the CSP.

    The default password is r1+@z(9Ho3b.

    Time-out period (s):

    Timeout period, within which the device must respond to the message sent by the eSight. If the device does not respond within the timeout period, the eSight considers that the device does not exist.

    The default value is 30.

  4. Click OK.

    NOTE:

    To create more devices, click Apply.

    • If the device has been created successfully, the AddMO Success dialog box is displayed. Click OK in the dialog box.
    • If the device fails to be created, the Error dialog box is displayed, showing the failure cause. Click OK in the dialog box and set device parameters again.

Operation Result

  1. Choose Resource > Intelligent Video Surveillance from the main menu.
  2. In the navigation tree, choose Resource Management > Monitoring Platform.

    If you can find the new devices in the management object list, the devices are added successfully.