Agile POL Solution Configuration Guide 02

This document describes the service configuration guide for Huawei Agile POL solution, including enterprise campus, hotel, and campus scenarios. Service configuration cases include data, IP phone, Wi-Fi, VoD, and video surveillance.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring GPON Type B Single-Homing (OLT Dual-Homing)

Configuring GPON Type B Single-Homing (OLT Dual-Homing)

This chapter introduces the configuration guide of GPON Type B single-homing protection (OLT Dual-Homing).

Usage Scenario

GPON Type B single-homing protection (OLT Dual-Homing):

NOTE:
GPON Type B single-homing protection (OLT Dual-Homing):
  • OLT upstream link run LAG (Link Aggregation Group ).
  • L3 Switch run E-Trunk.
  • L3 switch configuration VRRP as a user gateway.

Data Planning

Table 5-3  GPON Type B Single-Homing Protection data planning

Item

OLT

Protection group ID

0

PON port

  • Work Port: 0/1/0
  • Protect Port: 0/2/0

Upstream port

  • Active Port: 0/3/0
  • Standby Port: 0/4/0
NOTE:

Data planning for example data, the actual service configuration, please use the specific network data planning.

Procedure

  1. Configure OLT.
    1. Configure link aggregation group.

      To add ports 0/3/0 and 0/4/0 into a lacp static aggregation group in ingress mode.

      huawei(config)#link-aggregation 0/3/0 0/4/0 ingress workmode lacp-static

    2. Run the protect-group command to create a protection group.

      huawei(config)#protect-group 0 protect-target gpon-uni-port workmode timedelay

    3. Run the protect-group member command to add a member to the protection group.

      huawei(protect-group-1)#protect-group member port 0/1/0 role work
      huawei(protect-group-0)#protect-group member port 0/2/0 role protect

    4. Run the protect-group enable command to enable the protection group.

      By default, a protection group is disabled after it is created.

      huawei(protect-group-0)#protect-group enable
      huawei(protect-group-0)#quit

    5. Save the data.

      huawei(config)#save

  2. (Option) Configure L3 Switch.

    Taking Huawei S12700 switch as an example.

    1. Create Eth-Trunk and configura Eth-Trunk mode.

      <SwitchA> system-view
      [SwitchA] interface eth-trunk 1
      [SwitchA-Eth-Trunk1] mode lacp   //Configure Eth-Trunk 1 to work in LACP mode.
      [SwitchA-Eth-Trunk1] port link-type trunk   //Set the link type of Eth-Trunk1 to trunk.
      [SwitchA-Eth-Trunk1] port trunk allow-pass vlan 2 to 4094   //Add Eth-Trunk1 to VLANs 2 to 4094.
      

    2. Add port to Eth-Trunk.

      Run the eth-trunk command adds an interface to an Eth-Trunk.

      [SwitchA] interface gigabitethernet 1/0/3
      [SwitchA-GigabitEthernet1/0/3] eth-trunk 1
      [SwitchA-GigabitEthernet1/0/3] quit
      [SwitchA] interface gigabitethernet 1/0/4
      [SwitchA-GigabitEthernet1/0/4] eth-trunk 1
      [SwitchA-GigabitEthernet1/0/4] quit
      

    3. For configuration VRRP Please refer to the L3 Switch configuration guide.

Configuration Script

Configure OLT
link-aggregation 0/3/0 0/4/0 ingress workmode lacp-static
protect-group 0 protect-target gpon-uni-port workmode timedelay
protect-group member port 0/1/0 role work
protect-group member port 0/2/0 role protect
protect-group enable
save
Translation