Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Adding Storage Resources

Adding Storage Resources

Scenarios

Log in to the FusionStorage Manager (FSM) node and configure the iSCSI function. Then, create a logical unit number (LUN) in the storage pool based on service planning and connect the LUN to Hyper-V.

Prerequisites

Conditions

FusionStorage Block has been configured.

Data

The management plane IP addresses and iSCSI plane IP addresses of all controller VMs (CVMs) have been obtained.

Software

You have obtained FusionStorage Block V100R006C20SPC200_tool.zip.

Procedure

    Enable the iSCSI function for all CVMs.

    1. On the FusionStorage Block Self-Maintenance Platform, choose Resource Pool > Block Storage Clients.
    2. Select all CVMs in the right pane.
    3. Click Configure iSCSI.

      A dialog box is displayed, showing all selected CVMs.

    4. Click Enabled.

      A warning dialog box is displayed.

    5. Click OK to enable the iSCSI function for selected CVMs in batches.
    6. On the Block Storage Clients page, locate the row that contains the first CVM, click More, and select Configure iSCSI Port.

      A dialog box is displayed.

    7. Click Add.

      A dialog box is displayed.

    8. Set the following parameters:

      • iSCSI IP: Set it to the iSCSI plane IP address of the CVM.
      • Port: Set it to 3260.

    9. Click OK.

      The Configure iSCSI Port window is closed, and the iSCSI port is successfully added.

    10. Add iSCSI ports for all CVMs. For details, see 6 to 9.

    Configure iSCSI storage and connect the hosts to the Hyper-V.

    1. After configuring iSCSI on FSM, you can configure the iSCSI storage based on the planned services. For details about configuration operations, see Block Storage Service > Configuration > Block Storage Service Administrator Guide > Resource Management in FusionStorage Product Documentation .

      After FusionStorage Block is installed and configured, you can use FusionStorage Block storage resources.