Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Network

Network

Table 3-5 describes the network requirements.
Table 3-5  Network requirements
Category Requirement

Computing node

  • NICs on physical servers support the single-network-port mode (used for the eBackup and CVM nodes) as well as the active-backup (bond mode 1) bonding mode.
  • In the event of 10GE/25GE networking, at least 2 x 10 Gbit/s or 2 x 25 Gbit/s networking.
  • The NIC types and network types are as follows: 10GE (TCP/IP), 40 Gbit/s InfiniBand (RDMA), 56 Gbit/s InfiniBand (RDMA), 10GE RoCE (RDMA), and 25GE RoCE (RDMA).
  • It is recommended that the physical network latency between computing nodes and storage nodes be less than 1 ms and packet loss rate be less than 3%.
  • RoCE v1 NICs cannot be interchanged with RoCE v2 NICs.
  • A local link IPv6 address starting with FE80 and a multicast IPv6 address starting with FF00 cannot be used. In addition, HyperMetro and remote replication cannot be used when IPv6 addresses are used.

Storage node

  • Port bonding must be configured for the NICs on physical servers, and the port bonding mode is active-backup (bond mode 1). If the bond mode is not configured or the bond mode is not set to 1, the network suboptimal health check mechanism will not take effect.
  • In the event of 10GE/25GE networking, at least 2 x 10 Gbit/s or 2 x 25 Gbit/s networking.
  • On a 40 Gbit/s or 56 Gbit/s InfiniBand network, the bandwidth can meet the requirements.
  • The NIC types and network types are as follows: 10GE (TCP/IP), 25GE (TCP/IP), 40 Gbit/s InfiniBand (RDMA), 56 Gbit/s InfiniBand (RDMA), 10GE RoCE (RDMA), and 25GE RoCE (RDMA).
  • When rack-level security is used, at least four 10 Gbit/s NICs are required for communication between cabinets, each server provides at least two 10 Gbit/s NICs, and the storage plane provides at least two 6 Gbit/s NICs.
  • It is recommended that the physical network latency between computing nodes and storage nodes be less than 1 ms and packet loss rate be less than 3%.
  • RoCE v1 NICs cannot be interchanged with RoCE v2 NICs.
  • A local link IPv6 address starting with FE80 and a multicast IPv6 address starting with FF00 cannot be used. In addition, HyperMetro and remote replication cannot be used when IPv6 addresses are used.