RH2288 V3 V100R003C00SPC703B010 iBMC V300 Release Notes 01

  • Favorite
  • Download
Published On:2018-05-18
Views:650
Downloads:94
Document ID:EDOC1100018996
RH2288 V3


iBMC V300 Release Notes


Issue 01

Date 2018-5-07




HUAWEI TECHNOLOGIES CO., LTD.
Copyright © Huawei Technologies Co., Ltd. 2018. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.


Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.


Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.




Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://enterprise.huawei.com




Issue 01 (2018-5-07) Huawei Proprietary and Confidential i
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 1 V300 Release Notes




Contents

1 V300 Release Notes ....................................................................................................................... 1
2 V294 Release Notes ....................................................................................................................... 3
3 V276 Release Notes ....................................................................................................................... 5
4 V262 Release Notes ....................................................................................................................... 7
5 V253 Release Notes ..................................................................................................................... 10
6 V245 Release Notes ..................................................................................................................... 11
7 V243 Release Notes ..................................................................................................................... 12
8 V242 Release Notes ..................................................................................................................... 13
9 V241 Release Notes ..................................................................................................................... 14
10 V239 Release Notes ................................................................................................................... 15
11 V236 Release Notes ................................................................................................................... 16
12 V228 Release Notes ................................................................................................................... 18
13 V218 Release Notes ................................................................................................................... 20
14 V216 Release Notes ................................................................................................................... 21
15 V212 Release Notes ................................................................................................................... 22
16 V210 Release Notes ................................................................................................................... 23
17 V206 Release Notes ................................................................................................................... 25
18 V202 Release Notes ................................................................................................................... 26
19 V201 Release Notes ................................................................................................................... 27
20 V193 Release Notes ................................................................................................................... 29
21 V191 Release Notes ................................................................................................................... 30
22 V182 Release Notes ................................................................................................................... 31
23 V162 Release Notes ................................................................................................................... 33



Issue 01 (2018-5-07) Huawei Proprietary and Confidential ii
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 1 V300 Release Notes

24 V151 Release Notes ................................................................................................................... 34
25 V138 Release Notes ................................................................................................................... 35
26 V135 Release Notes ................................................................................................................... 36
27 V126 Release Notes ................................................................................................................... 38
28 V123 Release Notes ................................................................................................................... 39
29 V116 Release Notes ................................................................................................................... 40
30 Virus Scan Result ...................................................................................................................... 41




Issue 01 (2018-5-07) Huawei Proprietary and Confidential iii
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 1 V300 Release Notes




1 V300 Release Notes

Release Date
2018-5-07

Current Version
V300

Earlier Version
V294

What's New
Optimized the process of creating and deleting logical disks under out-of-band RAID
management.
Optimized SNMP V1 / V2 community name login mode.
Added support for uploading upgrade files via redfish post operations.
Added support for configuring BIOS setup menu items multiple times via the redfish
interface.
Added support for French interface in WEB.
Optimize the processing flow of network driver receiving abnormal packets.
Optimized the packet sending policy of DNS.
Added support for KVM-compatible Japanese keyboard functionality.
Added support for obtaining the CPU clock frequency through the redfish interface.
Added support for PCIE card BDF information acquisition.
Optimized the power module alarm policies.
Added support for SSDP to report the ProductName function.
Added support for using ipmiutil tools for enabled/disabled user functions.
Optimized the scanning strategy of the management health sensor.



Issue 01 (2018-5-07) Huawei Proprietary and Confidential 1
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 1 V300 Release Notes

Added support for LDAP certificate chain authentication.
Added support for the virtual media mounted via HTTPS Protocol.

Precautions
iBMC V300 works with BIOS V387. After upgrading the iBMC to V300, you must upgrade
the BIOS to V387.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 2
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 2 V294 Release Notes




2 V294 Release Notes

Release Date
2018-3-29

Current Version
V294

Earlier Version
V276

What's New
Optimized LDAP domain account login process.
Optimized the information display for the Japanese interface.
Optimized the description of the hard disk speed in the redfish interface.
Optimized the time zone menu on the WebUI to solve the problem that some city names are
duplicate.
Optimized the display of pCIeDeviceDevicename under the pcieDevice node queried using
SNMP.
Optimized the displayed of PCIe card information on the WebUI.
Optimized the information displayed when the speed of the front and rear fans is queried
using SNMP.
Optimized the RTC voltage alarm threshold.
Optimized the display of the NVMe disk information.
Added monitoring of the SSD service life.
Added monitoring and alarms about CE overflow of the memory, QPI, and PCIe.
Enhanced FDM diagnosis, and optimized fault collection, fault analysis, and diagnosis
functions.
Modified the description of the RAID card firmware version.


Issue 01 (2018-5-07) Huawei Proprietary and Confidential 3
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 2 V294 Release Notes

Optimized the information display for the Japanese interface.
Upgraded the PHP version to 5.6.32 for solving the industry's known vulnerabilities,
including CVE-2017-11143, CVE-2017-16642, CVE-2017-11145, CVE-2017-11146,
CVE-2017-11142, CVE-2017-7890, CVE-2017-11144, CVE-2017-11628 and
CVE-2017-12933.
Upgraded the APR version to 1.6.3 for solving the industry's known vulnerabilities, including
CVE-2017-12613.
Upgraded the curl version to 7.56.1 for solving the industry's known vulnerabilities, including
CVE-2016-3739, CVE-2016-5421, CVE-2016-0754, CVE-2016-7167, CVE-2016-4802,
CVE-2016-5420, CVE-2016-7141, CVE-2016-0755, CVE-2016-5419 and CVE-2017-9502.
Upgraded the httpd version to 2.4.29 for solving the industry's known vulnerabilities,
including CVE-2017-9798.

Precautions
iBMC V294 works with BIOS V387. After upgrading the iBMC to V294, you must upgrade
the BIOS to V387.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 4
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 3 V276 Release Notes




3 V276 Release Notes

Release Date
2018-2-2

Current Version
V276

Earlier Version
V262

What's New
Optimized the mechanism for recording memory ECC event logs.
Optimized the messages displayed on the Firmware Upgrade page on the iBMC WebUI.
Optimized the insertion and ejection of the virtual DVD-ROM drive for the KVM.
Optimized the description of the watchdog timeout event on the iBMC.
Optimized the format of the sensor names for the Trap event code mode.
Added redfish interface for getting logical disk information.
Added redfish interface to get the status of RAID card BBU.
Optimization for serial port information print during the process of one-click collection.
Upgraded the Apache Portable Runtime version to 1.6.3 for solving the industry's known
vulnerability(CVE-2017-12613).
Added support to clear security logs and action logs by CLI.
Optimized hard drive manufacturers information display.
Added redfish interface to get the status for all the RAID controllers.
Added redfish interface to get the status for all the power units.
Added redfish interface to get the status for all the hard disks.
Added redfish interface to disable the writable status of SNMP V2C.


Issue 01 (2018-5-07) Huawei Proprietary and Confidential 5
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 3 V276 Release Notes

Added support the system automatically power up after powered off due to the
over-temperature of cpu.
Added redfish interface to get the status for all the temperature of devices.
Added redfish interface to get the status for all the fan modules.
Added redfish interface to get the uptime of BMC.
Added redfish interface to get the token value of KVM.
Optimized to get the MAC information of PCIE card by CLI.
Optimized the reset event log description of system.
Optimized the information display for the Japanese interface.
The size of the video file is reduced to prevent one-click information collection failures in
special scenarios.
The mechanism for displaying the power supply health status queried through the Redfish
interface in power redundancy mode has been optimized.
Optimize handling Patrol scrub UCE.

Precautions
iBMC V276 works with BIOS V387. After upgrading the iBMC to V276, you must upgrade
the BIOS to V387.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 6
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 4 V262 Release Notes




4 V262 Release Notes

Release Date
2017-11-21

Current Version
V262

Earlier Version
V253

What's New
Optimize iBMC custom three-level certificate chain import method.
Optimize SNMP V1 / V2 community name login mode.
Optimize iBMC self-signed certificate time, consistent with local time.
Optimization to restore the factory default operation, support the operation log and so on.
Added support for Thermal Policy production, IPV6 customization.
Optimize redfish alarm level, keep an interface alarm consistent.
Optimize the interface IPV6 address display, solve the configuration IPV6, the interface
shows the IP address is empty.
Optimize the user experience of non-full-screen remote KVM, solve the operation of the
VMVARE on the left side of the menu bar, the use of the keyboard direction keys, KVM on
the right side of the scroll bar also with the moving problem.
Fix the nexpose scan of a serious vulnerability World writable files exist
(unix-world-writable-files).
Added support for daylight saving time.
To optimize the user in the SSL certificate import, configuration file import, click the upgrade
interface when the restart button WEB prompt information.
Optimize Web page resolution tips.



Issue 01 (2018-5-07) Huawei Proprietary and Confidential 7
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 4 V262 Release Notes

Upgrade java open source software to solve the industry common vulnerability
(CVE-2017-10125、CVE-2017-10101、CVE-2017-10109、CVE-2017-10105、
CVE-2017-10096、CVE-2017-10198、CVE-2017-10087、CVE-2017-10090、
CVE-2017-10243、CVE-2017-10102、CVE-2017-10067、CVE-2017-10081、
CVE-2017-10086、CVE-2017-10118、CVE-2017-10108、CVE-2017-10114、
CVE-2017-10176、CVE-2017-10115、CVE-2017-10078、CVE-2017-10111、
CVE-2017-10107、CVE-2017-10116、CVE-2017-10089、CVE-2017-10053、
CVE-2017-10135、CVE-2017-10110、CVE-2017-10074).
Optimizing the Accuracy of Memory Problem Location under Optimized High Temperature.
Upgrade PHP open source software version, fix PHP industry common vulnerability
CVE-2017-11628.
Optimize the virtual drive pop-up experience to solve the pop-up drive failure, repeated
access to the drive to start the problem.
Optimize how LDAP logs in IPV6 mode.
Optimize the LDAP configuration to solve the problem that the LDAP group can not be
configured normally in the root directory when configuring the user group information in the
LDAP configuration interface.
Optimize the time to log in to iBMC using LDAP.
Added support for query BOM encoding.
Added support for 3516 RAID card.
Upgraded the Apache HTTP Server version to 2.4.27 for solving the industry's known
vulnerabilities, including CVE-2017-9788 and CVE-2017-9789.
The web log filtering function has been optimized to eliminate incorrect content filtered.
The new version has removed the abnormal page display occurred when the language of the
browser is German.
Upgraded the SQLite version to 3.21.0 for solving the industry's known vulnerabilities,
including CVE-2016-6153 and CVE-2017-10989.
The mechanism for checking CPU configuration has been optimized. An alarm will be
generated if no CPU is detected.
Optimizes the fan speed adjustment mechanism for X540 net card.
In the earlier version, default parameters cannot be used to create RAID through the Redfish
interface. This problem has been resolved in the new release.
The Status attribute of the Manager resource is added for the Redfish interface.
The hardware alarming mechanism of the RAID card has been optimized to prevent false
alarms in certain scenarios.
The OAM detection is added for NICs.
The SOL function can be used through the CLI.
The function of querying and configuring the DST is added.
LDAP proxy user authentication is supported, and the bound LDAP proxy account and
password can be configured.



Issue 01 (2018-5-07) Huawei Proprietary and Confidential 8
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 4 V262 Release Notes

The GUID display sequence has been optimized.

Added support for Intel P4600 NVME disk;Added support for SAMSUNG PM1725a NVME
disk.
The function of disabling inactive accounts is added.
The function of displaying remote virtual devices is supported on the OS.

Precautions
iBMC V262 works with BIOS V380. After upgrading the iBMC to V262, you must upgrade
the BIOS to V380.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 9
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 5 V253 Release Notes




5 V253 Release Notes

Release Date
2017-11-10

Current Version
V253

Earlier Version
V245

What's New
Optimize LDAP login time.
Optimize independent kvm client ldap login compatible with special characters.
Optimize the command line hanging in the virtual media, automatically pop-up drive.
Optimize iBMC login mode, modify the host name can also be accessed from the browser.
Optimize the restart prompt for the iBMC upgrade interface.
Optimize iBMC to set the resolution when prompted.
Optimize how LDAP is logged on in IPV6.
Optimize the display of out-of-band raid management, not for raid cards that are not
supported.

Precautions
iBMC V253 works with BIOS V379. After upgrading the iBMC to V253, you must upgrade
the BIOS to V379.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 10
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 6 V245 Release Notes




6 V245 Release Notes

Release Date
2017-8-7

Current Version
V245

Earlier Version
V243

What's New
Optimize snmp oid display.
Added support for iBMC IP and SN numbers on KVM.
Added support for P4500 NVME disk.

Precautions
iBMC V245 works with BIOS V371. After upgrading the iBMC to V245, you must upgrade
the BIOS to V371.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 11
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 7 V243 Release Notes




7 V243 Release Notes

Release Date
2017-6-6

Current Version
V243

Earlier Version
V242

What's New
Optimize SNMP query time.

Precautions
iBMC V243 works with BIOS V363. After upgrading the iBMC to V243, you must upgrade
the BIOS to V363.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 12
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 8 V242 Release Notes




8 V242 Release Notes

Release Date
2017-5-19

Current Version
V242

Earlier Version
V241

What's New
Optimize LDAP configuration, support for input Lithuanian language.
Optimize BMC outbound mail time display to keep alarm event time consistent with BMC
current time.
Optimize KVM usage scenarios to resolve port issues when virtual media can not connect to
problems.

Precautions
iBMC V242 works with BIOS V363. After upgrading the iBMC to V242, you must upgrade
the BIOS to V363.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 13
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 9 V241 Release Notes




9 V241 Release Notes

Release Date
2017-5-8

Current Version
V241

Earlier Version
V239

What's New
Upgraded the JRE version to solve the industry's known vulnerabilities(CVE-2016-5548、
CVE-2016-5546).
Added support for Lithuanian language configuration LDAP.
Added support for IB card (MCX456A-ECAT, MCX455A-ECAT), acceleration card
(CNN5560-750-NHB-G, 8950-SCCP).

Precautions
iBMC V241 works with BIOS V357. After upgrading the iBMC to V241, you must upgrade
the BIOS to V357.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 14
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 10 V239 Release Notes




10 V239 Release Notes

Release Date
2017-3-29

Current Version
V239

Earlier Version
V236

What's New
Added support for uboot upgrade online.
Optimized the dual RAID alarm reporting mechanism to eliminate false BMC alarms in
special scenarios.



Precautions
iBMC V239 works with BIOS V357. After upgrading the iBMC to V239, you must upgrade
the BIOS to V357.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 15
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 11 V236 Release Notes




11 V236 Release Notes

Release Date
2017-2-25

Current Version
V236

Earlier Version
V228

What's New
The BMC starts to support P3700 Intel SSD cards from this version.
The BMC starts to support one-click collection of PSU logs.
Optimized the logging mechanism to prevent system event logs (SELs) from being
overwritten by exceptional logs.
The BMC supports enable the local KVM Client.
Optimized the domain user login mechanism to solve the following problem: If a user is
assigned to a domain only in user property configuration but not in domain member
configuration, the user cannot log in.
Optimized the BMC power-on policy to solve the problem that the server does not power on
immediately upon the BMC power-on after the PSUs are shortly disconnected.
Optimized the VCORE sensor alarm threshold to prevent low-probability incorrect alarm
reporting.
Added support for CLI-based SSL certificate import.
Added support for non-root users to perform pinging.
Added support for SCP.
Optimized the logging mechanism to prevent system event logs (SELs) from being
overwritten by exceptional logs.
Added support for obtaining in-band information.


Issue 01 (2018-5-07) Huawei Proprietary and Confidential 16
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 11 V236 Release Notes

Added support for out-of-band RAID configuration management.
Added support for Redfish interfaces.
Optimized the LDAP login rules to allow logins with a full name.
Added support for importing certificate chains.
Optimized the network port auto-adaption mode to prevent low-probability ping packet loss.
Upgraded the PHP version to solve the industry's known vulnerabilities, including
CVE-2016-6290 and CVE-2016-9936.
Added support for mounting virtual media through the CLI.
Added support for importing and exporting basic configurations of the BMC and BIOS.
Optimized the domain user login mechanism to solve the following problem: If a user is
assigned to a domain only in user property configuration but not in domain member
configuration, the user cannot log in.
Optimized the PCIe card slot number display.



Precautions
iBMC V236 works with BIOS V357. After upgrading the iBMC to V236, you must upgrade
the BIOS to V357.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 17
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 12 V228 Release Notes




12 V228 Release Notes

Release Date
2016-12-06

Current Version
V228

Earlier Version
V218

What's New
Deleted the support for telnet to enhance security.
Optimized the user account lock mechanism. User accounts will be locked when the number
of incorrect password attempts reaches the limit.
Supported import of the SSL certificates containing special character "-".
Optimized LDAP implementation to enable iBMC access with LDAP login name and
multi-level directory supported by user groups.
Supported query of SSD disk endurance and firmware information.
Supported query of DDR3 and DDR4 DIMM type and SN information.
Supported query of information about the number of CPU cores, total number of threads,
cache size, and processor ID.
Supported start of the remote console using the Java Network Launch Protocol (JNLP).
Supported query of ES3000 V3 card information, such as the SN, model, endurance, and
firmware version.

Upgraded OpenSSL to remove known vulnerabilities. (CVE-2016-5696、CVE-2016-5389)

Upgraded OpenSSH to remove known vulnerabilities. (CVE-2016-3115、CVE-2016-8858)
Supported NVIDIA M4 GPU cards.
Supports NTP out-of-band configuration.


Issue 01 (2018-5-07) Huawei Proprietary and Confidential 18
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 12 V228 Release Notes




Precautions
iBMC V218 works with BIOS V350. After upgrading the iBMC to V228, you must upgrade
the BIOS to V350.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 19
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 13 V218 Release Notes




13 V218 Release Notes

Release Date
2016-08-30

Current Version
V218

Earlier Version
V216

What's New
Added the function of configuring the IP address and gateway at the same time in one
command in the BMC command line interface.
Modified the memory ECC event description to: "DIMM### correctable ECC."
Added the function of supporting Ubuntu system clients on the remote virtual KVM.
Provided a secondary development SNMP interface to supports network interface mode
switching.
Updated the RAID controller card name on the E9000 product WebUI.
Added the function of supporting Umate LDAP group setting.



Precautions
iBMC V218 works with BIOS V335. After upgrading the iBMC to V218, you must upgrade
the BIOS to V335.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 20
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 14 V216 Release Notes




14 V216 Release Notes

Release Date
2016-08-30

Current Version
V216

Earlier Version
V212

What's New
Solved the following problem: The keyboard does not work on the KVM screen if the local
client runs SUSE 11.
Solved the following problem: Magic keys do not work if ipmitool is used to log in over SOL
to a server running Linux.
Realized the customization requirements of Baidu sensors.
Added support for Alibaba PTAS.



Precautions
iBMC V216 works with BIOS V331. After upgrading the iBMC to V216, you must upgrade
the BIOS to V331.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 21
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 15 V212 Release Notes




15 V212 Release Notes

Release Date
2016-08-19

Current Version
V212

Earlier Version
V210

What's New
Enabled LDAP to support the NTLM protocol.
Enabled commands on the CLI to generate screenshot files.



Precautions
iBMC V212 works with BIOS V330. After upgrading the iBMC to V212, you must upgrade
the BIOS to V330.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 22
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 16 V210 Release Notes




16 V210 Release Notes

Release Date
2016-07-29

Current Version
V210

Earlier Version
V206

What's New
Optimized the web online help to solve the low-probability problem that online help cannot
be displayed properly
Optimized the enginetime mechanism of SNMP traps to solve the problem that some NMSs
encounter errors in receiving SNMP traps
Changed the predictive failure alarm severity to major
Added the support for the syslog feature
Upgraded the FDM function to version 2.1 to enhance the system error locating capability
Added the support for SSH public key authentication (PKA)
Added the CLI login function for LDAP users
Added the out-of-band monitoring and query function for RAID configurations of the
LSISAS3108 and LSISAS3008 controller cards
Optimized the IPMI module to support ipmitool 1.8.14
Upgraded OpenSSH to 1.0.1t to solve vulnerabilities (including CVE-2016-5600)
Enhanced security so that Telnet is disabled by default for newly created users
Upgrade the OpenSSH to version 7.1p2 to solve vulnerabilities, including CVE-2016-0778,
CVE-2016-1907, CVE-2016-0777, and CVE-2016-3115
Enhanced security by prompting users to change the default password upon login


Issue 01 (2018-5-07) Huawei Proprietary and Confidential 23
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 16 V210 Release Notes

Enhanced security by allowing each BMC account to log in to only one web session at a time
Set the KVM cursor acceleration to be enabled by default to better synchronize the local and
remote cursors
Optimized the KVM so that it supports more JRE versions, uses the CA signature certificate
by default, and provides better user experience for PCs connected through the Internet
Optimize the KVM keyboard processing mechanism, solve the Tab key in the remote KVM
inside the probability of failure.
Fixed the brute force cracking vulnerability.
Fixed the information leak vulnerability.
Fixed the weak encryption algorithm vulnerability.
Fixed the uncontrolled resource consumption vulnerability.
Solved the following problem: iBMC of the RH2288 V3 reports the “eth1 link down” error,
but the OS and switches do not have faulty links.



Precautions
iBMC V210 works with BIOS V327. After upgrading the iBMC to V210, you must upgrade
the BIOS to V327.
iBMC V205 or later does not support users with empty passwords. If iBMC is upgraded from
an earlier version to 205 or later, users with empty passwords cannot log in to iBMC




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 24
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 17 V206 Release Notes




17 V206 Release Notes

Release Date
2016-03-14

Current Version
V210

Earlier Version
V206

What's New
Upgraded GlibC. Resolved the (CVE-2015-7547) loophole..
Optimized the WebUI and the description of the KVM power-on and power-off. The
description is clearer..
Optimized password security by prohibiting empty passwords.
Optimized the SSL certificate import function. Resolved the problem that after the CSR file is
generated for multiple times, importing the certificate fails.
Users in customer role group can execute one-click collection on WebUI.
User can login to iBMC web from eSight withe SSO functionr.
Implement WEB security outstanding practice, the same BMC login account can only have an
online session.



Precautions
iBMC V206 works with BIOS V322. After upgrading the iBMC to V206, you must upgrade
the BIOS to V322.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 25
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 18 V202 Release Notes




18 V202 Release Notes

Release Date
2016-03-14

Current Version
V202

Earlier Version
V201

What's New
Optimized the fan speed adjustment policy..
Added the fault diagnosis function for Intel Broadwell E5V4 CPUs.
Added the support for the Japanese keyboard in KVM.
Added the support for ES3000 V3 SSDs.
Added the support for SM236 NICs
Resolved the BMC function errors caused by log compression failures that occasionally occur.
Added the M30 and M40 GPU fan speed adjustment function.

Precautions
iBMC V202 works with BIOS V316. After upgrading the iBMC to V202, you must upgrade
the BIOS to V316.
.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 26
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 19 V201 Release Notes




19 V201 Release Notes

Release Date
2016-02-23

Current Version
V201

Earlier Version
V193

What's New
Resolved the problem that fan modules occasionally run at a high speed after server power-on
and power-off.
Resolved the problem that iBMC cannot power on or off devices after server power-on and
power-off.
Optimized the compatibility with the FreeIPMI tool to resolve the problem that errors are
reported when users query iBMC FRU information on the OS.
Optimized the compatibility between MIB files and Spectrum to resolve Spectrum's failure to
compile MIB files.
Resolved the problem that incorrect RAID controller card quantities are occasionally
displayed on the iBMC WebUI.
Optimized the PSU status query function of the SNMP interface by adding the PSU absence
state.
Installed the official SNMP software patch to defend against the 05840BRG vulnerability of
SNMP 5.7.3.
Upgraded the open source software PCRE to 8.37 to defend against the following CVE
vulnerabilities: CVE-2015-8395, CVE-2015-8386, CVE-2015-8388, CVE-2015-8384,
CVE-2015-8390, CVE-2015-8389, CVE-2015-8391, CVE-2015-8394, CVE-2015-8385,
CVE-2015-8392, CVE-2015-8387, CVE-2015-8393, CVE-2015-8381, CVE-2015-8383,
CVE-2015-8380




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 27
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 19 V201 Release Notes

Added the LDAP multi-domain management function (up to three LDAP servers can be
configured.
Added the LDAP multi-domain management function (up to three LDAP servers can be
configured.
Optimized the MCE and "CAT ERROR" diagnosis function.
Added the function for managing Broadwell E5 v4 series CPUs.
Optimized the out-of-band management of PCIe SSDs so that users can query SSD
information such as capacity and manufacturers.
Added the functions for querying and configuring the SNMP Trap mode.
Added the function for upgrading the Huawei 750 W PSU firmware.
Added the support for SM236, SP245, SM251, and SP230 cards.

Precautions
iBMC V201 works with BIOS V178. After upgrading the iBMC to V201, you must upgrade
the BIOS to V178.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 28
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 20 V193 Release Notes




20 V193 Release Notes

Release Date
2016-01-07

Current Version
V193

Earlier Version
V191

What's New
Resolved the occasional garbled characters in SOL log files downloaded from the web
system.
Resolved the problem that the BMC is abnormal due to the long-time use of the SNMP client.

Precautions
iBMC V193 works with BIOS V169. After upgrading the iBMC to V193, you must upgrade
the BIOS to V169.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 29
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 21 V191 Release Notes




21 V191 Release Notes

Release Date
2015-11-03

Current Version
V191

Earlier Version
V182

What's New
Added the function for starting the remote console through URL.
Added the SD card management function
Added the PCIe SSD management function.
Optimized the fault diagnosis function to enable users to correctly locate faulty components.
Added the JRE version download link on a page of the iBMC web system.
Added the function for cancelling IP address configuration.
Added the function for disconnecting the KVM upon timeout.
Added the function for using the ipmitool command to set an SNMP community name.
Resolved the occasional reconnection failures upon abnormal SOL disconnections.
Resolved the failures to refresh power consumption data or present alarms in the iBMC web
system.

Precautions
iBMC V191 works with BIOS V169. After upgrading the iBMC to V191, you must upgrade
the BIOS to V169.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 30
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 22 V182 Release Notes




22 V182 Release Notes

Release Date
2015-10-08

Current Version
V182

Earlier Version
V162

What's New
Resolved the KVM and remote desktop compatibility problem in case of using a 32-bit
browser in a 64-bit operating system
Resolved the problem that the BMC may have a duplicate engine ID
Resolved the problem that the accumulated power consumption value is incorrect
Resolved the problem that the English interface and prompts may show Chinese characters
Optimized alarms of PCIe devices, including RAID controller cards and I/O modules
Resolved the problem that the thermal trip alarm persists after it triggers a power-off
Resolved the problem that the BMC may encounter errors in case of pressing CTRL+D in the
CLI
Resolved the problem that the disk numbers are not sequential
Resolved the problem that the WebUI of the upgraded BMC can be used only after the
browser cache is cleared
Resolved the problem that the CPU2 alarms are displayed as CPU1 alarms
Optimized a warning message for use of NMIs
Included the video recording and screen capturing functions in the one-click collection
function




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 31
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 22 V182 Release Notes

Resolved the problem that the displayed backup version is incorrect after a BMC version
rollback
Resolved the problem that the SNMP and web interfaces provide different fan alarm levels

Precautions
iBMC V182 works with BIOS V157. After upgrading the iBMC to V182, you must upgrade
the BIOS to V157.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 32
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 23 V162 Release Notes




23 V162 Release Notes

Release Date
2015-7-20

Current Version
V162

Earlier Version
V151

What's New
Support virtual folder functionality.
Support for power supply mode (Active-standby)
Web support port mapping function
Support for stateless computing
Support PTAS features
Support for custom role management
Support over IPv6 IPMI LAN

Precautions
iBMC V162 works with BIOS V156. After upgrading the iBMC to V162, you must upgrade
the BIOS to V156.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 33
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 24 V151 Release Notes




24 V151 Release Notes

Release Date
2015-5-7

Current Version
V151

Earlier Version
V138

What's New
Optimizes fan speed adjustment of the ES3000 V2 SSD card.
Permanently deletes the original Iptable parameters after configuring with new ones.
Solves the problem that the mouse and keyboard cannot be used normally in some special
scenarios after the RAID 3108 card is configured.
Solves the problem that the BMC LDAP function is related to the LDAP server configuration.
Solves the problem that BIOS configuration is lost after BIOS is upgraded, if the ME data
area changes.
Optimizes the PCIe SSD card identification and heat dissipation and supports the default
RAID 1 of the two SD cards.
Solves the problem that the BMC runs slowly and abnormally caused by the LCD module
memory leakage.
Solves the problem that the BMC function is abnormal caused by the SNMP module handle
leakage.
Solves the following problem: There is a low probability that esight software fails to upgrade
the CPLD.

Precautions
iBMC V151 works with BIOS V138. After upgrading the iBMC to V151, you must upgrade
the BIOS to V138.


Issue 01 (2018-5-07) Huawei Proprietary and Confidential 34
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 25 V138 Release Notes




25 V138 Release Notes

Release Date
2015-4-2

Current Version
V138

Earlier Version
V135

What's New
Solves the problem that the sensor for detecting fan module installation status is abnormal.
"Solves the problem that the freeipmi bmc-info command cannot be executed in Linux."
Solves the problem that BMC is abnormal caused by pressure tests using the IPMItool in the
OS.

Precautions
iBMC V138 works with BIOS V130. After upgrading the iBMC to V138, you must upgrade
the BIOS to V130.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 35
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 26 V135 Release Notes




26 V135 Release Notes

Release Date
2015-3-4

Current Version
V135

Earlier Version
V126

What's New
Optimized the Restore Factory Settings option, allowing only an administrator has the right to
restore factory settings.
Solved the problem that BMC login fails over FTP, Telnet, and SSH if a power failure occurs.
Added the function of setting the power-off timeout over SNMP.
Solved the problem that indicator and component information on the WebUI needs to be
updated manually. The information can be updated automatically.
Solved the problem that the sender's password is not set successfully when a message
indicating that the setting is successful is displayed on the Alarm Email Notification Settings
page.
Solved the problem that the last-screen function cannot record the information displayed on
the last screen when a server is powered off
Optimized black box function. This function can be enabled or disabled when a server is
powered on or off.
Solved the problem that sensor historical alarms for PCIe cards cannot be parsed after the
BMC resets or is powered off.
Updated the time to 2014-2015 and updated the description to "Copyright Huawei
Technologies Co., Ltd. 2004-2015. All rights reserved".
Solved the problem that the power-on policy option cannot be restored to the default setting
after the factory settings are restored.


Issue 01 (2018-5-07) Huawei Proprietary and Confidential 36
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 26 V135 Release Notes

Supported ES3000 V2 PCIe SSDs.
Supported active and standby PSUs.
Optimized fan speed adjustment policy for PCIe GPUs.
Optimized NC-SI adaptive function for PCIe card configuration, allowing the function to be
still effective after the PCIe card is installed in another slot.
"Optimized management network port adaptive function.Fixed network port selection
sequence: dedicated BMC network port, onboard network ports (1, 2, 3, and 4), and PCIe card
network ports (1 and 0)"
Added FDM fault diagnosis function.
Upgrade glibc components to solve CVE-2015-0235 vulnerability.

Precautions
iBMC V135 works with BIOS V130. After upgrading the iBMC to V135, you must upgrade
the BIOS to V130.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 37
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 27 V126 Release Notes




27 V126 Release Notes

Release Date
2014-12-29

Current Version
V126

Earlier Version
V123

What's New
Optimizes a fan speed adjustment technology to provide heat dissipation capacity, ensuring
C..
that it can stably operate for a long term at an ambient temperature of 45°
Solves the problem that the BMC time zone may fail to be set using IPMItool..
Solves the problem that no information is displayed when four GPUs are installed.
Avoids Windows of the Chinese version when a user log in to the WebUI of the English
version for the firs time.
Solves the problem that the function of one-time automatic BIOS SETUP login takes effect
again when this function is enabled.

Precautions
iBMC V126 works with BIOS V126. After upgrading the iBMC to V126, you must upgrade
the BIOS to V126.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 38
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 28 V123 Release Notes




28 V123 Release Notes

Release Date
2014-12-02

Current Version
V123

Earlier Version
V116

What's New
New rules apply to user login user LDAP groups.
Added fan model display in WEB page.
Added NEW user rights management features in WEB page, you can configure the user have
no permission to use KVM.
Added NSCI function for Intel PCIE NIC Card.
Support Freeipmi tool to use SOL.
Support DCM feature.
Support IPMI commands to entering the BIOS SETUP.
Added LDAP to support NTLM authentication mechanisms.
Support TRAP OID function.

Precautions
iBMC V123 works with BIOS V123. After upgrading the iBMC to V123, you must upgrade
the BIOS to V123.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 39
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 29 V116 Release Notes




29 V116 Release Notes

Release Date
2014-10-16

Current Version
V116

Earlier Version
N/A

What's New
This issue is the first release version.

Precautions
iBMC V116 works with BIOS V119. After upgrading the iBMC to V116, you must upgrade
the BIOS to V119.




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 40
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 30 Virus Scan Result




30 Virus Scan Result



30.1.1.1 防病毒扫描说明

1. Scan Detail:

Engine Name Avira
Engine Version 8.03.42.028
Virus Lib Version 7.12.130.046
Scan Time 2016-10-27 11:30:09.014
Scan Result OK

Engine Name Kav
Engine Version 10.1.0.867
Virus Lib Version 20161027-060012
Scan Time 2016-10-27 11:27:47.784
Scan Result OK

Engine Name McAfee
Engine Version 5800:7501
Virus Lib Version 8330:0
Scan Time 2016-10-27 11:27:07.433
Scan Result OK

Engine Name Symantec
Engine Version 12.1.2015.2015
Virus Lib Version 2016-10-26r7
Scan Time 2016-10-27 11:24:15.427
Scan Result OK

Engine Name OSCE
Engine Version 9.850.1008
Virus Lib Version 1285900
Scan Time 2016-10-27 11:23:55.124
Scan Result OK



Issue 01 (2018-5-07) Huawei Proprietary and Confidential 41
Copyright © Huawei Technologies Co., Ltd.
RH2288 V3
iBMC V300 Release Notes 30 Virus Scan Result




Issue 01 (2018-5-07) Huawei Proprietary and Confidential 42
Copyright © Huawei Technologies Co., Ltd.
Note:The preview effect may be slightly different from that of the source document. You can download the document and view it on your local PC.